SBIR/STTR Research Award

Prospective/Retrospective Motion Correction System for Motion Robust Pediatric MR

Award identifier 5f9d9008a69bbd2d6908f801309bae4f2939953eea6243c29654688e8ccdc802Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,760,945

Program and phase

STTR · Phase II

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ROBIN MEDICAL INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
S38NM2MSMM14
Solicitation number
PA11-097
Topic code
NIMH

Research abstract

DESCRIPTION (provided by applicant): The long term objective of the project is to develop a new motion robust magnetic resonance imaging (MRI) technology. Magnetic resonance imaging is a powerful tool that aids in the diagnosis of individual subjects, guides their clinical care, ad provides insights into the mechanisms of normal and atypical development. The characterization of mental health disorders across the lifespan has been facilitated by brain MRI. However, conventional magnetic resonance imaging requires the subject being imaged remain perfectly still for the duration of the image encoding. Young children and non-cooperative adult patients have difficulty to hold still long enough for successful imaging. For clinical imaging such patients are frequently sedated or anesthetized, which runs the risk of adverse events, is costly, and does not ensure the subjects remain perfectly still. Research studies are typically unable to use sedation or anesthesia due to its significant risk. This hampers our ability to identify the neurobiological underpinnings of mental health disorders. The development of motion robust magnetic resonance imaging will enable dramatic improvements in our capacity to chart the trajectory of mental illness over the lifespan. This willhave a significant impact on our ability to determine when, where and how to intervene, and enable improved evaluation of potential interventions. The project proposes to utilize a combination of hardware for prospective motion tracking during scan and post-acquisition processing with scattered data interpolation to enable the construction of high resolution high signal-to-noise ratio images of the brain from subjects who are unable to hold still. The specific aims of this Phase II STTR application are: (1) to modify the EndoScout tracking system to enable realtime motion tracking on any scanner, with no hardware connections to the scanner and with no software changes in the scanner; (2) to accelerate retrospective processing time to achieve rapid reconstruction of motion-free 3D image set and thus to enable clinical evaluation of the scans before the subject is taken out of the scanner; (3) to apply the method to additional sequences that are needed for clinical use of the system; (4) to conduct technical tests with a moving phantom and volunteer tests to verify the performance of the system before its being used in the clinical studies: (5) to conduct a two-phase clinical study of the system, including a try first without sedation study in the general pediatric population and in Tuberous Sclerosis patients. This is a joint project by Robin Medical, Inc., which will develop the motion tracking system and the accelerated processing software and will conduct technical tests of the system; and the Research Section at the Department of Radiology, Children's Hospital Boston, which will develop the imaging sequences and will conduct the volunteer and clinical studies of the project. PUBLIC HEALTH RELEVANCE: The proposed project aims to enable MRI in children and non-cooperative adults without sedation or anesthesia. If successful, it will reduce healthcare costs as sedation or anesthesia for MRI doubles or triples the cost of the scan; it will expand the use of MRI in children and non-cooperative adults to smaller hospitals that do not have the required resources to conduct MRI under sedation or anesthesia; and it will eliminate the risks associated with sedation or anesthesia and thus will enable to expand the use of MRI to clinical and research application where it is now not being used due to associated risks.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

24 SBIR/STTR records share this UEI (1998–2020). Reported award amounts total $18,932,366. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.