SBIR/STTR Research Award

Noninvasive Multiple Inert Gas Elimination Technique

Award identifier dab779b34c3da3bb3cf80286c14be2c6d927ed3efbe1bbec6efd3f3f45a0164eAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$106,274

Program and phase

SBIR · Phase I

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MEDICAL PHYSICS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2010-2
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): Insufficient oxygenation of the blood (hypoxemia) is a common symptom in ICU patients, and may be caused by a combination of four different pathologies: 1) decreased alveolar ventilation (hypoventilation), 2) oxygen diffusion limitation, 3) inequality in ventilation/perfusion, and 4) shunts. Hypoxemia can be assessed by any of the following physiological parameters: 1) arterial PO2 and PCO2, 2) difference in alveolar and arterial PO2, 3) venous admixture (known as a physiological shunt), and 4) physiological dead space. However, while these parameters are clinically useful, they offer quite limited information and are subject to misinterpretation when the underlying assumptions are not met. For the most part, the exact causes of hypoxemia are difficult to distinguish in any given patient using presently available tools. A multiple inert gas elimination technique (MIGET) was introduced in the early 1970s as a way to overcome many of the limitations imposed by the classical methods mentioned above. The uniqueness of MIGET is its use of inert gas data to quantitate the many pathological features of O2 and CO2 gas exchange in the acutely ill. Taking advantage of simpler gas exchange models applied to inert gases (compared to O2 and CO2), MIGET provides quantitative distributions of ventilation and blood flow with respect to Vand / Qand ratio. It is the acquisition of these distributions that form the basis for the many calculations of O2 and CO2 gas exchange parameters that MIGET provides. Importantly, a special strength of MIGET is that it distinguishes regions of low Vand A / Qand ratio from unventilated regions (shunt), and also regions of high Vand A / Qand ratio from unperfused lung. MIGET also allows additional insights into gas exchange, which include 1) identification of the presence of diffusion limitation for O2, and 2) quantification of the role of extrapulmonary factors on arterial PO2 and PCO2 gas exchange limitation. However, MIGET has never evolved from a research tool to a clinical management tool due to: 1) measurement time delays; 2) operational complexity; and 3) substantial invasiveness. The goal of this proposed work is to develop and validate the instrumentation and methodology that provides the complex Vand / Qand distribution and analysis of MIGET - but without the cited disadvantages. PUBLIC HEALTH RELEVANCE: For over 30 years, MIGET (Multiple Inert Gas Elimination Technique) has been a valuable research tool used to understand and characterize lung abnormalities. Physiological information from this technique could greatly improve therapy in the Intensive Care Unit (ICU), but the highly invasive methods make it impractical in any clinical setting. This proposed Non-Invasive MIGET System (NIMS) has the potential to provide MIGET information to improve patient management both in and outside of the ICU.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.