SBIR/STTR Research Award

New Needle for Two-Needle Hemodialysis

Award identifier 2527d4547bba55d4d29ea8094122f142cab1f1b76eaaf5d03447f05ffd8e11c4Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$502,342

Program and phase

SBIR · Phase II

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
BIOMEDICAL ENTERPRISES INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
MVC2BR72ALR1
Solicitation number
PHS2010-2
Topic code
NIDDK

Research abstract

DESCRIPTION (provided by applicant): Studies performed with phase I SBIR grants 1R43DK55385-01A1 and 1 R43 DK59062-01A1 and phase II SBIR grants 2R44DK059062-02A1 and 5R44DK059062-04 have demonstrated the following: a) A new hemodialysis(HD) venous needle (NVN) with three jets is hemodynamically superior to the current venous needle (CVN) because it decreases the velocity of the vascular access flow by 3.5 times and the turbulence by 6 times when compared with the currently used venous needle (CVN), and unlike the CVN, it does not form an area of annular recirculation. b) The NVN is more efficient than the CVN in the removal of BUN, it is safe(it causes equal or less damage to cells, it does not form clots and does not cause prolonged bleeding at puncture sites), and it is as effective as the CVN to fulfills the function of conduit to transport blood. c) More importantly, the data from HD in sheep and patients suggest that the NVN is clinically superior to the CVN because it causes less damage to circulating blood cells and less generation and release of cytokines and oxidants. However, the data did not show statistically significant superiority because the sample size was small. The proposed phase II competing renewal grant will demonstrate clinical superiority of the NVN by studying a larger number of HD patients and obtaining statistically significant data. Seventy stable HD patients will be studied. Each patient will receive one mid-week HD using the CVN and one mid-week HD using the NVN the following week. Pre and post HD plasma and intracellular IL-1 and IL-6, intracellular IL-6 soluble receptor, IL-6 gp130, superoxide and hydrogen peroxide and plasma Mandenyldealdehyde(MDA) and advanced oxidation protein products(AOPP) will be measured. Each patient will use the same HD prescription during both HD including length of dialysis, type of dialyzer non-reused, size of needles (15g), heparin, dialysate composition, and blood and dialysate flow rate. The outcomes to be compared are net changes in blood levels of all the markers in the NVN and CVN groups. Demonstrating that the NVN is clinically superior will have great significance: a) It will show that the NVN is more useful than the CVN: The NVN would decrease the complications caused by inflammation and oxidative stress, the mortality of patients and the cost of care, b) It will allow claiming clinical superiority of the NVN in the application for pre-market approval to be submitted to the FDA. This will facilitate marketing and sales and is necessary to obtain investments to commercialize the needle. The NVN fills a technological gap and a clinical need: the CVN is not fit for use with the 400-500 ml/min blood flow rates currently used in HD. The NVN is protected by several patents and the process to obtain a 510K from the FDA has been started. PUBLIC HEALTH RELEVANCE: This project will demonstrate that the new venous needle (NVN) is a product that will help hemodialysis patients unlike the current venous needle (CVN) that is harmful to patients. The NVN will decrease medical complications, mortality and the cost of care of hemodialysis patients. The NVN fills a technological gap and a clinical need: The current venous needle (CVN) fulfills the needs of hemodialysis with low blood flow rates but it is not fit for use with the high blood flow rate currently used of 400-500 ml/min. This study will enhance scientific knowledge to improve the delivery of dialysis and the design of devices used on dialysis.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

9 SBIR/STTR records share this UEI (1993–2010). Reported award amounts total $1,916,739. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, National Aeronautics and Space Administration

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.