SBIR/STTR Research Award

Validation of a Novel Automated Seizure Detection and EEG Trending System for Con

Award identifier e8f27a7c3ddab248aeea9f2e30413874093a34c30a0b10e480b0c3585bc9e9beAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$333,146

Program and phase

SBIR · Phase I

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Optima Neuroscience, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA11-096
Topic code
NINDS

Research abstract

DESCRIPTION (provided by applicant): Increased recognition of the incidence of nonconvulsive seizures (NCSs) in critically ill patients has led to a growing demand for continuous EEG monitoring in Intensive Care Units (ICUs). However, one of the biggest challenges to the expanding use of continuous EEG monitoring in the ICU lies in the difficulty of providing a timely review of clinical data by EEG experts. As a result, though EEG is being recorded continuously, ICU physicians may not be alerted to the occurrence of seizures until several hours later, following thorough review of the raw EEG by specialized personnel. The end result is compromised patient care and the inability to make appropriate real-time treatment decisions. Automated seizure detection software is occasionally used to assist in the EEG review process. However, existing seizure detection software is inadequate for most ICU patients because of the abnormal background EEG and highly variable seizure discharges that occur in encephalopathic patients. These EEG patterns differ greatly from those patterns that occur in epilepsy monitoring units (EMUs). As a result, commercially available software performs poorly when used with critical care patients, resulting in missed seizures and a high incidence of false detections. While available EEG-trending software is more useful, there are significant technical limitations in existing algorithms: 1) inability to show clear changes for bref, focal or slowly evolving, low frequency seizures, 2) low specificity in differentiating NCSs that require urgent treatment from other abnormalities, which are usually not treated with anti-seizure medicines, and 3) limited scientific evidence of clinical utility - none are FDA approved for ICU use. The overall goal of this SBIR project is to develop and commercialize an accurate, reliable, and user-friendly ICU seizure monitoring and alert system, CereScope . The system will feature a novel automated seizure detection algorithm, ICU-ASDA, with a high sensitivity (gt 85percent) and low false detection rate (lt 0.2/hr or 5/day). To enhance the system sensitivity, it will also be interfaced with artifact-reduced novel quantitative EEG (qEEG) trending, a Seizure Index (SI) which facilitates rapid recognition of potentialseizure patterns by visual inspection. CereScope will automatically create and transmit digital graphic files containing detected events for immediate expert review. Having completed the design and training studies for the ICU-ASDA, in this Phase I project we propose a clinical study to statistically evaluate and validate the performance of the algorithm that will meet the FDA's requirements. In addition, we will conduct studies at four Neuro-ICUs to investigate how combining qEEG trending with the results from the detection algorithm can enhance overall performance of the system. The specific aims of this Phase I feasibility study are: 1) Conduct a clinical study to evaluate the performance (sensitivity and false detection rate) of a novel seizure detection algorithm, ICU-ASDA, in EEG recordings from acutely ill adult patients, and 2) Investigate the utility of novel qEEG trends for enhancing sensitivity in identifying NCSs in long-term ICU EEG recordings when used in conjunction with the ICU-ASDA. Successful commercialization of the CereScope system will improve the recognition and management of seizures in critically ill patients. PUBLIC HEALTH RELEVANCE: Increased recognition of the high incidence of seizures in critically ill patients has ledto a growing demand for continuous brain monitoring in Intensive Care Units (ICUs). However, one of the biggest challenges to the expanding use of continuous brain monitoring in the ICU is the difficulty of providing a timely review of the high volumes ofEEG (brain electrical activity signal) data by experts, resulting in an inability to make appropriae real-time treatment decisions and compromised patient care. The overall goal of this SBIR project is to develop a novel system for EEG analysis that willallow ICU physicians, technicians, and nurses to rapidly identify seizures as well as other abnormal changes in brain function.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.