SBIR/STTR Research Award

Treatment of Sleep Apnea using a Positive Airway Pressure Rebreathing Modulator

Award identifier c9ea3ef1f53d7534ad8855fd1b69dcf19307c2c7aa5251068131e52778b8a486Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$284,156

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
CLEVELAND MEDICAL DEVICES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
LKM3SMX1MMM5
Solicitation number
PA10-050
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): Although obstructive sleep apnea has received the lion's share of recognition and investigation in research and practice, more troubling forms of sleep apnea, like those that are mediated by chemoreflex instability, exist and continue to have inadequate treatment. Central apneas and periodic breathing (now called the Cheyne Stokes breathing pattern) are the classic polysomnographic markers of strong chemoreflex modulation of sleep apnea. A recently described variant, complex sleep apnea , demonstrates sustained induction of central apneas or severe periodic breathing during positive pressure titration for what seems to be obstructive disease on the diagnostic polysomnogram. The number of the affected population is large,especially when specific populations such as congestive heart failure are considered. It is estimated that complex sleep apnea alone makes up 10%-15% of the overall sleep apnea patient population or over 1.5 million patients (assuming a conservative estimate of 10 million overall sleep apnea population). In those with significant chemoreflex modulatory effects, the probability of failure of conventional positive airway pressure therapy is high. Positive airway pressure therapies tend to flush out and reduce the level of carbon dioxide (CO2); prevention of this hypocapnia state during the application of positive airway pressure therapies is an important stabilizing factor for chemoreflex-modulated sleep apnea syndromes. The Positive Airway Pressure Gas Modulator (PAPGAM), a new class of positive airway pressure device designed to prevent chemoreflex instability by carefully maintaining CO2 levels just above the CO2-dependent apneic threshold, has shown excellent acute results. Chronic effects with a modified dead space approach, called Enhanced Expiratory Rebreathing Space, have shown some success, but are less precise than directly controlling the CO2 level. This proposal will investigate the use of exhaled air to provide the CO2 that is mixed with the inlet air of the positive airway pressure device. By controlled mixing, we hope to completely eliminate the need for the high pressure tank, or at a minimum markedly increase its life. Thus, the aim is to obtain the precision of PAPGAM treatment but with reduced cost, marked improvements in ease of use, and minimized adverse outcomes from technical failures. The goals of the phase I research include: 1) building prototypes capable of diverting or pulling the exhaled air from the patient to the inlet of the positive airway pressure device; 2) determining if a passive or an active rebreathing mechanism is required; 3) determining what maximum concentrations are possible using each technique; and 4) clinically assessing the system. Successful implementation will result in a poweful new treatment for chemoreflex-modulated sleep apnea. PUBLIC HEALTH RELEVANCE: Abnormal control of breathing during sleep causes central or mixed forms of sleep apnea and is especially common in heart failure and kidney failure patients. The usual treatment for obstructive sleep apnea, a mask and air pressure device, does not work well in those with central / mixed sleep apnea. Recent research indicates that the air pressure device decreases the normal level of carbon dioxide and excellent treatment results have been achieved by increasing carbon dioxide levels back to normal levels. The proposed research will develop methods to use carbon dioxide exhaled by the patient to provide stability of breathing patterns during sleep. Successin development of this device, called the Positive Airway Pressure Rebreathing Modulator (PAPREM, to be used with air pressure treatments) will markedly improve treatment of complicated forms of sleep apnea.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

104 SBIR/STTR records share this UEI (1992–2016). Reported award amounts total $44,360,204. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, National Science Foundation, Department of Education

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.