SBIR/STTR Research Award

QUASI-MONOCHROMATIC X-RAY SOURCE FOR MAMMOGRAPHY

Award identifier ac72bf03ac1601f98cb768e794f95fb08d345b4860f47e993056dcf18355f478Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$757,892

Program and phase

SBIR · Phase II

Award year

2002

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ADELPHI TECHNOLOGY INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
FE2HY976FJW7
Solicitation number
Not reported
Topic code
Not reported

Research abstract

Description (provided by applicant): The objective of the proposed research is to construct a prototype narrow-bandwidth x-ray source for mammography using a thin, efficient hybrid radiator driven by a relativistic electron beam of moderate energy and current. The high x-ray yield (photons/electron) of the source permits the use of modest electron-beam currents, preventing thermal damage to the radiator itself. The radiator is thin, permitting the electron beam to pass through it many times, thereby proportionally increasing the emitted x-ray flux. Since the source is inherently collimated and quasi-monochromatic, it will produce higher quality radiographic images while lowering the dose to the patient. Phase I experiments have demonstrated intense quasi-monochromatic x-rays in the range optimum for mammography (15 to 25 keV). Calculations of the x-ray yield and the average current passing through the radiator have demonstrated that there is adequate flux for imaging. The research will proceed by improving the design of the thin hybrid radiator and experimentally demonstrating its feasibility by producing images of inanimate phantoms. The potential for successful development of the prototype imaging system is very high because our Phase I research has already experimentally demonstrated, both electron recycling and narrow bandwidth, tunable x-ray generation. These results indicate that a high quality mammogram can be generated in less than 3 seconds.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

120 SBIR/STTR records share this UEI (1984–2025). Reported award amounts total $33,799,637. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Energy, Department of Health and Human Services, National Science Foundation, Department of Defense, Department of Homeland Security, National Aeronautics and Space Administration

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.