SBIR/STTR Research Award

Ultra-High Resolution Magnetometers Based on APF SQUIDs

Award identifier 75e3854b093984fb9f0e345690887d91721077d3543d505dc67451f9404345a5Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$749,971

Program and phase

SBIR · Phase II

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
HYPRES INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
Z3BBX7KX4WU5
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The objective of the proposed research is to develop Ultra-High Resolution, thin film low-temperature superconductivity (LTS) SQUID Magnetometers (UHRSM) with integrated pickup-loops and Additional Positive Feedback (APF). The UHRSM will be optimized for imaging of the magnetic fields produced by action currents, injury and developmental currents, remnant magnetization, and magnetic susceptibility in isolated living tissue and small experimental animal preparations. As a collaborative effort between HYPRES and several research institutions, including Living State Physics of Vanderbilt University, analog SQUID magnetometers are being developed for imaging applications. In order to utilize SQUIDs for these applications, their voltages are amplified by a step-up transformer so it could be instrumented with room temperature electronics. The use of a step-up transformer requires extensive peripheral electronics for linearization, thus limiting the number of SQUID magnetometer channels in a practical system. We are proposing to develop a novel SQUID with APF that eliminates the need for the transformer, and as a result simplifies the peripheral electronics significantly. The proposed APF SQUID integrates an on-chip feedback coil with the SQUID. This can increase the gain of the device substantially, and as a result no step-up transformer is required for read out. The proposed research involves the staged development and implementation of a SQUID design to enhance the spatial resolution and maximize the field sensitivity for specific applications. The existing expertise will be exploited further to develop and improve SQUID sensors for general and custom biomagnetic applications which require higher-sensitivity SQUID magnetometers and gradiometers but lower spatial resolution. An aggressive program of biophysical measurements at Vanderbilt coupled with the technical expertise at HYPRES will lead to both a commercially attractive UHRSM instrument and a valuable national capability for fabrication of new designs for SQUID sensors.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

255 SBIR/STTR records share this UEI (1985–2025). Reported award amounts total $91,527,586. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Energy, National Aeronautics and Space Administration, National Science Foundation, Department of Health and Human Services, Department of Commerce

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.