SBIR/STTR Research Award

Multichannel Electrosonic Actuation Microarray for Cell-Based Screening

Award identifier fd2e3c5d353d5fb45915cab6a6777bb13692837a55c109941d564084b747ea1cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$158,708

Program and phase

SBIR · Phase I

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
OPENCELL TECHNOLOGIES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Q6HJH3BNJH96
Solicitation number
PHS2010-2
Topic code
NCRR

Research abstract

DESCRIPTION (provided by applicant): High-throughput, parallel delivery and transfection of biologically relevant material into cells remains a difficult task. The proposed work addresses this issue through integration of multiple Electrosonic Actuation Microarrays (EAMs) into a single MIST (Multiple Integrated Sample Treatment) device that is optimized for parallel drug and/or gene/nucleic acid delivery and transfection into several cell samples via precise control of biophysical action (i.e., concurrent sono/mechanoporation and electroporation). The device format is compatible with existing large-scale cell-handling equipment. The EAM is a microelectromechanical systems (MEMS)-enabled device that ejects a sample containing biological cells through microscopic (of order size of a single cell) nozzles with incorporated electroporation electrodes, thereby opening pores in the cell membrane via combined mechano/electroporation for uptake of nanomaterials. The high ultrasonic frequency of operation and array format enable fast processing of large cell populations (up to millions of cells per second). A single reservoir system can accommodate a wide range of prescribed volumes, from ~100 nL to arbitrarily large sample sizes. By arraying EAM together, MIST enables parallel and uniform treatment of several different samples simultaneously. Economical fabrication enables fluid handling components of the device to be made disposable, which eliminates cross-sample contamination. MIST is suited to basic/applied research, as well as diagnostic and therapeutic uses. Design, development and evaluation of cell treatment by MIST will build on experience gained through characterization of a multimode bench-top-scale prototype, STEAM (Single-sample Treatment via Electrosonic Actuation Microarray). A growing understanding of the bioeffects induced in certain cell types during EAM treatment will facilitate the transition to a multichannel device. MIST development has the potential to greatly accelerate discovery of cancer therapies by enabling simultaneous screening of synthetic small interfering RNA (siRNA) for different effects on cell function. Demonstrating the feasibility of our approach will open opportunities for commercialization of MIST in other markets. The primary objective of this Phase I SBIR is to expand our single-sample STEAM platform into the multi-sample MIST device and to demonstrate parallel delivery and transfection of multiple biomolecules into different cell samples. To achieve this objective, (1) a MIST platform that is optimized for cell treatment will be developed, and (2) safe handling with regard to viability and proliferation, uniformity of treatment, and the transfection capabilities of MIST will be evaluated using standard cell assays, confocal fluorescence microscopy and flow cytometry. In addition, MIST treatment will be compared with conventional lipofectamine-mediated and electroporation-based transfection. PUBLIC HEALTH RELEVANCE: Development of a MIST (Multiple Integrated Sample Treatment) platform will address the current need for high-throughput, parallel delivery and transfection of biologically relevant material into cells. Further, because the device format is compatible with existing large-scale cell handling equipment (e.g., 384-well plate-based systems), it has the potential to accelerate discovery of potential cancer therapies through efficient screening of large complementary DNA (cDNA) and small interfering RNA (siRNA) libraries. Simultaneous transfection of multiple different DNA plasmids encoding fluorescent proteins using MIST, will demonstrate its feasibility in a wide range of drug discovery and gene therapy applications.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

8 SBIR/STTR records share this UEI (2009–2021). Reported award amounts total $4,718,152. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.