SBIR/STTR Research Award

Point-of Care System for Determination of Bilirubin Capacity in Neonates

Award identifier 5c7b2fda44db51a751cfc40f9842e1a8f54c1558c7ad393960c973c00673396cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$826,992

Program and phase

SBIR · Phase II

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
AVIV BIOMEDICAL INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA11-096
Topic code
NIBIB

Research abstract

DESCRIPTION (provided by applicant): Uncontrolled hyperbilirubinemia (jaundice) in neonates has long been known to lead to neurological dysfunction including irreversible athetoid cerebral palsy with speech, ocular and hearing impairments, and even death.Contemporary management is based upon monitoring the total serum bilirubin (TBS), taking into account other clinical parameters such as birth weight and gestational age, and administering effective treatment (phototherapy and/or the rare exchange transfusion), if dictated. Unfortunately, the trend towards discharge of apparently healthy neonates from the hospital very soon after birth has made the management of subsequent jaundice more difficult in that population. A long suggested, but not used, better predictor of the neonate's risk for neurological sequelae due to elevated bilirubin is a measure of the capacity to sequester bilirubin in the blood compartment by its binding to serum albumin. The concentration of unbound bilirubin, the driver for bilirubinescaping from the vasculature, can be calculated from the TBS and binding capacitl. Presently existing methods for assaying binding capacity and unbound bilirubin are not facile. However, all these parameters can be directly measured simply in a very smallvolume of whole blood with a special purpose fluorometer, the hematofluorometer, first described years ago, by making use of the natural fluorescence of bilirubin bound to albumin. This technology is amenable to point-of-care use. The aims of this project are to transform the modernized and miniaturized hematofluorometer developed in Phase I into a product suitable for operation in various point-of-care environments, including the intensive care and healthy baby nurseries, the neonatal inpatient clinic, and the pediatrician's office. The first aim is to optimize the basic optical and electronic design: redesin the electronics to support the hospital information management requirements, such as a bar code reader, printer, and interface with a computer, either directly or via the local internet. The second aim is to develop a reagent kit that is easy to use and inexpensive. Phase I work demonstrated that significantly more work is needed to design a kit meeting these requirements, and then scaling this design up into a product that can be mass produced. The third aim is to test the instrument with neonate blood samples in a clinical environment to demonstrate that it well suited to meet the needs. With this goal in mind, Stanford University's Medical School and Children's Hospital has agreed to participate as a subcontractor to evaluate the new technology. With these proposed improvements, the instrument will be ready for the next stages: releasing it to the market for immediate RandD uses and clinical studies, and eventual approval by the FDA for general use. PUBLIC HEALTH RELEVANCE: A long suggested, but not used, better predictor of the neonate's risk for neurological sequelae due to elevated bilirubin is a measure of the capacity to sequester bilirubin in the blood compartment by its binding to serum albumin. The concentration of unbound bilirubin, the driver for bilirubin escaping from the vasculature, can be calculated from the TBS and binding capacitl. Presently existing methods for assaying binding capacity and unbound bilirubin are not facile. However, all these parameters can be directly measured simply in a very small volume of whole blood with a special purpose fluorometer, the hematofluorometer, first described years ago, by making use of the natural fluorescence of bilirubin bound to albumin. This technology is amenable to point-of-care use.The aims of this project are to transform the modernized and miniaturized hematofluorometer developed in Phase I into a product suitable for operation in various point-of-care environments, to complete development of easy-to-use sample handling disposables, and to verify the performance of the system for samples from a specified population of neonates.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.