SBIR/STTR Research Award

Microfabricated Implantable Flowmeter for CSF Shunts Phase II

Award identifier 40e34aa685b192c374bfff61d17d4cf43e1dcc739719c73ca2265ab6958f9045Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$3,003,413

Program and phase

SBIR · Phase II

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
VIVONICS INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
NSULT5XTTNJ5
Solicitation number
PA09-206
Topic code
NINDS

Research abstract

DESCRIPTION (provided by applicant): An implantable wireless flow sensor system has been under development that would enable measurement of the flow of cerebrospinal fluid (CSF) through the ventriculoperitoneal (VP) shunt, currently used to treat hydrocephalus patients. CSF flow is a key indicator of shunt function, and there is currently no way to measure it in situ, resulting in the absence of clinical methods to directly assess shunt function or to predict its failure. Using MEMS microfabrication methods, the proposed flow sensor will be manufactured at a size small enough to be integrable with implanted VP shunts. The key elements in the flow meter are capacitive structures that change properties with change in CSF flow. Electromagnetic coupling between the internal passive circuitry and an external handheld circuit allows implantation of the flow sensor without the need for implanted batteries or transcutaneous wires. The proposed Phase II project will build on the encouraging results of Phase I, which demonstrated the wireless interrogation of proof-of-concept MEMS sensors and the presence of a readily measurable relationship of flow to the resonance of the sensor. In Phase II, fully-function flow-sensing MEMS chips will be manufactured, as well as arevised handheld unit that will display and output flow, based on the known relationship between flow rate and resonance. In vitro testing will establish calibration for the sensor implants, and will demonstrate measurement accuracy over the full physiological range of CSF flow, over long periods of time, and with appropriate phantom models. In parallel, a chronic sheep hydrocephalus model will be in preparation, along with implementation of appropriate packaging, biocompatibility, and sterilizability intothe sensor implant prototypes, as well as consideration of MR compatibility. Performance of an animal test protocol shall evaluate the sensor in regard to (1) sensitivity and specificity with regard to detection of flow obstruction, (2) CSF flow measurement accuracy, and (3) effect on shunt patency. PUBLIC HEALTH RELEVANCE: Every year there are approximately 23,000 shunt revisions performed in the U.S., in order to correct the relatively common failure of ventriculoperitoneal (VP) shunts used totreat hydrocephalus patients. However, children are still dying from shunt failure, and studies indicate that earlier detection would save a large fraction of these children. An implantable, wireless CSF flow meter would enable the clinician to monitor shunt function during routine office visits (rather than waiting for the re-appearance of hydrocephalus symptoms), allowing detection of impending shunt failure, avoidance of lifesaving treatment on an emergency basis, and reduction of mortality associated with VP shunt failure.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

44 SBIR/STTR records share this UEI (2006–2024). Reported award amounts total $27,600,936. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Health and Human Services, National Aeronautics and Space Administration

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.