SBIR/STTR Research Award

High Resolution Mammography Sensor

Award identifier 418187a2dcc99d0312b7a1c3c9bcf93d87168f3638109711db95aa0d6d95d7d6Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$977,915

Program and phase

SBIR · Phase II

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
RADIATION MONITORING DEVICES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
SCKQA85YU4U4
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Radiation Monitoring Devices ( RMD') is developing a digital radiographic imaging technology that is based upon a semiconductor x-ray receptor. The more specific, targeted application is mammographic imaging (including breast tomosynthesis) for which the benefits of this technology will later be described. At the core of this research, RMD is developing the process for creating direct imaging' x-ray detectors fabricated from polycrystalline layers of the semiconductor m ercuric iodide (HgI2). A significant part of this work will involve tailoring the electrical, chemical and physical properties of these layers for the intended purpose. To utilize HgI2 as an x-ray receptor, it must be coupled with an amorphous silicon (a-S i) thin film transistor (TFT) array. The TFT array provides pixelation, charge storage and frame readout necessary to form a complete imager. In order to enable digital mammography to achieve its full potential and thereby, have a major clinical impact, x- ray detection technology needs to be advanced. RMD is investigating a direct' detection method using mercuric iodide (HgI2) as the x-ray detector. The HgI2 film acts as the sensor, detecting the incoming x-rays with high quantum efficiency due to its high x-ray stopping power. The detected x-ray image is converted directly into an electronic charge image due to the formation of electron-hole pairs in HgI2. Due to efficient collection of these charges with minimal lateral spreading, this approach does not s uffer from the light spreading effects observed in phosphors and thereby, provides high detection efficiency as well as high spatial resolution. HgI2 has nearly ideal characteristics for mammography such as high stopping efficiency, large gain, good charge transport, and good stability. Finally, the method by which RMD is proposing to deposit the HgI2 films is highly cost effective and can be used to readily cover large areas, making it very complimentary to the large sized a-Si:H TFT arrays that are increa singly becoming available. RMD plans to deposit and test the key HgI2 layers on two types of substrates: 1) simple conductive plates for testing electrical bulk properties, and 2) a range of a-Si TFT arrays that will provide the key imaging data. RMD will perform all the fabrication tasks associated with the layers and conduct most evaluations on the simpler devices. To aid with the a-Si TFT tasks, RMD has joined with two collaborators Varian Medical Systems and the University of Michigan to provide mater ials and expertise with testing. Dr. Mitchell Goodsitt of the University of Michigan has joined our team to provide guidance on the specific imaging requirements for high resolution mammography and digital breast tomosynthesis (DBT). Dr. Daniel Kopans and Richard Moore of MGH have also joined our team as clinical consultants. Dr. Kopans and Richard Moore are specialists in mammography and DBT and will provide guidance and input on clinical goals and evaluate our imagers under conditions applicable to digita l mammography and DBT. PUBLIC HEALTH RELEVANCE: RMD is proposing to develop a new type of mammography x-ray detector that holds the promise of very high spatial resolution and superior images at low exposure levels. The proposed fabrication technique is bo th cost effective and readily scaleable, both helping to remove manufacturing barriers that can impede adoption of technology.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

930 SBIR/STTR records share this UEI (1983–2026). Reported award amounts total $346,950,619. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Energy, Department of Health and Human Services, Department of Defense, National Aeronautics and Space Administration, National Science Foundation, Department of Homeland Security

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.