SBIR/STTR Research Award

Microwave sterilization of hemodialysis catheter systems

Award identifier 973f9bdb98749c123d7110862e09dc11f3b73ebc258967ac03b124b62b58aa27Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$225,659

Program and phase

SBIR · Phase I

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MED-CONDUIT, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA11-096
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): The survival of patients with end-stage renal disease (ESRD) on hemodialysis is largely dependent upon the maintenance of vascular access. Yet catheter related blood stream infection remains one of the most important causes of sepsis and repeat hospital admissions among hemodialysis patients. While observance of strict sterile technique and the use of chemical antiseptics to disinfect catheter connectors is accepted practice in hemodialysis units, these methods have notsignificantly reduced clinical infection rate. The use of antibiotic lock techniques has resulted in a modest reduction of catheter related infections, yet this practice is also known to accelerate the growth of antibiotic resistant specie. To address thisclinical need, Med-Conduit, Inc has developed a microwave sterilization device that enables the application of moist heat to saline filled connectors. The current Phase I research will be focused on the development of an in-vitro bench model to characterize the lethality of such microwave energy on bacteria populations present in finite volumes of liquid. Our long term goal will be to generate a system that exhibits rapid and energy efficient reduction of bacterial colony formation and biofilm deposition in the connectors used to attach a central venous catheter to a hemodialysis instrument. Our project will be designed to optimize the power and frequency of the underlying radio frequency signals, the shape of the signal-receiving antenna, the location andorientation of the target volume, and the shape and topology of the wave-guide structure in a manner that improves heat transfer and disinfection in the target volume and thus optimizes the rate and efficacy of disinfection. To address this goal, we propose the following Specific Aims: Aim 1: To complete the design of a microwave-based disinfection system for use in hemodialysis. Aim 2: Based on the system simulation, to fabricate and evaluate the heating capacity of a prototype disinfection system. Aim 3:To assess performance of prototype systems in terms of bacterial colony reduction. If this Phase I research is successful, we will propose in Phase II to design, fabricate and test a finalized device that meeting the practical demands of size, weight, andperformance of the clinical setting. PUBLIC HEALTH RELEVANCE: Catheter related bacteremia (CRB) comprises the most common reason for hospitalization for patients with end-stage renal disease (ESRD) undergoing chronic hemodialysis, accounts for nearly one third of the cost of disease management, and is associated with a mortality of 12-25.9%. The success of hemodialysis in provide life support to patients with ESRD remains inextricably linked to the ability to limit bacterial colonization of th access catheters and thereby to reduce the incidence of CRB. Current clinical practice, including the use strict sterile technique and various antibiotic delivery systems, has not been successful in ameliorating this problem. Med-Conduit has developed a microwave technology which promotes rapid heating of fluids at the catheter interface with the extracorporeal circuit, and thus promotes disinfection. The goal of this Phase I research will be to design, fabricate and test a novel microwave system to provide disinfection at the catheter interface with the hemodialysis system. If this Phase I research is successful, will be propose in Phase II to create a finalized device that meets the practical demands of size, weight and performance of the clinical setting.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.