SBIR/STTR Research Award

Simultaneous SPECT/CT with a single photon counting camera

Award identifier ce14ed2a2a67551443212e8ad887e2e16a8d4a644b184759e08db069c56e006aAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$150,574

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DXRAY, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA10-050
Topic code
NIBIB

Research abstract

DESCRIPTION (provided by applicant): This Phase I grant titled, Simultaneous SPECT/CT with a single photon counting camera will enable the development of a fast photon-counting x-ray and gamma-ray imaging array with energy discrimination. The aims of theproject when completed will demonstrate several advances in the technologies used to fabricate vertically integrated dense arrays. Recently, new technological developments in connecting sensors to the reduced size of application specific integrated circuits (ASICs) has been applied to reading out semiconductor detectors These advances, along with improvements to the cost and reliability of the compound semiconductor cadmium telluride (CdTe), allow us to develop a photon counting detector and read-out technology for higher spatial resolution single photon emission computed tomography (SPECT) and energy resolved single photon counting x-ray computed tomography (CT) at reduced dose. These detectors improve spatial resolution in SPECT imaging with direct conversion CdTe sensors and 0.5 mm pixels which are three times smaller than currently available commercially. These same detectors, which maintain good energy resolution up to 5 W 106 counts per second per pixel (the world's fastest output count rate), enablesignificant improvements in CT imaging such as reduced patient dose while maintaining excellent image quality, enhanced tissue contrast, and material decomposition capabilities (tissue type identification). Photon counting detectors with energy binning canimprove CT performance by counting and binning each x-ray detected. Additionally, the simultaneous acquisition of anatomical and functional data from identical image volumes will reduce coregistration errors which will be extremely important for the accurate anatomical localization of uptake on sub- millimeter length scales. This project produces several important technological innovations. These include the fabrication of single crystal CdTe detectors with an active area extending to the edge of the crystals (no guard rings) which allows tiling with almost no dead space. Additionally, we have developed packaging and encapsulation methods to connect dense multi channel fast application specific integrated circuits (ASICs) to the crystals and formed withinthe active area of the crystal to preserve tiling in two dimensions. And we achieve a rapid signal formation, shorter than the transit time for charge carriers across the CdTe crystal. In this Phase I project we will demonstrate a vertically integrated photon counting SPECT and CT detector with energy binning and read-out that is capable of producing higher spatial resolution SPECT and energy resolved CT which can deliver less radiation dose and differentiate between tissue types. Achieving vertical integration while maintaining performance will allow the tiling of Phase I modules in Phase II to larger fields of view. The innovative methods described in this proposal could have a tremendous significance by developing methods that improve SPECT and CT imaging and could one day be translated to the clinic. There remains however a large risk in the final integration of the vertical readout ASICs to the CdTe detectors. As we are developing the world's fastest x-ray and gamma-ray detector arrays by using the latest and smallest bonding techniques available, this is not a low risk step in the development. Completion of the Phase I milestones in a vertically integrated array will successfully address this risk as well as demonstrate significantly improved performance as compared to the currently available SPECT and CT detectors. PUBLIC HEALTH RELEVANCE: We are developing fast photon counting arrays for x-ray and gamma-ray imaging. This new detector technology can potentially reduce dose and improve contrast when applied to x-ray CT. Additionally, the detector can perform simultaneous SPECT and CT. The proposal submitted contains several innovative advancements to the current state of the art technologies employed in both CT and SPECT.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.