SBIR/STTR Research Award

Long-Term Non-Enzymatic Glucose Sensors for an Artificial Pancreas

Award identifier 995473ba887ba343d772cb59ad78bb0d492d82f28827cdccecc3c3eda64edabfAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$225,000

Program and phase

SBIR · Phase I

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
PROFUSA, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
FKJCB9NGPM24
Solicitation number
DK13-001
Topic code
NIDDK

Research abstract

DESCRIPTION (provided by applicant): Despite years of development, currently available continuous glucose monitors (CGMs) still lack good accuracy and reliability for short-term and particularly, long-term use in diabetes management. While insulin pumps work well, CGM remains the single largest hurdle to closing the loop of an artificial pancreas. The main obstacles to achieving a long-term, accurate CGM are instabilities in the sensing chemistry and the body's immune response against the sensor - specifically the foreign body response (FBR) - leading to biofouling, inflammation, avascular fibrosis and sensing chemistry degradation. Additionally, current CGM systems in the market and under development are either bulky percutaneous probes or implantable devices encased in hard metals or plastics that become surrounded by an avascular tissue capsule over time or are taken up by immune cells (if nano-sized). In this Phase I SBIR, we propose to demonstrate the feasibility of a minimally invasive, long-term, non-enzymatic glucose sensor produced using our novel, tissue-integrating smart hydrogels that become part of the tissue they are sensing to overcome the FBR. The near infra-red (NIR) fluorescence of the smart hydrogel modulates based on the glucose concentration and is detected non- invasively through the skin. The long-term, vascularizing nature of these hydrogel sensors provides exquisite capillary proximity to more than 1000 times greater sensor surface area compared to traditional electrochemical sensors, thereby overcoming the FBR and enhancing accuracy and longevity of glucose detection. The proposed CGM system contains no implanted electronics or hardware in the body. An external optical reader monitors interstitial glucose transdermally based on changes in the NIR optical signal. The optical reader takes the form of a thin-film micro-optical skin patch or a hand-held wand. PROFUSA's long- term goal is to develop a self-calibrating, injectable, soft hydrogel CGM with a minimum operational life of 3 months and a longer-term goal of 12 months with sufficient accuracy to enable an artificial pancreas. Moreover, because of the platform-nature of this technology, sensing nanospheres specific to other analytes (e.g. oxygen, lactate) can also be incorporated within the hydrogel matrix. PROFUSA's tissue-integrating sensor platform has been demonstrated to be stable in the body for months to years and to provide superior sensing performance compared to solid, non-tissue integrating sensors. The overall focus in this proposal is to extend the longevity of fluorescent sensing chemistry to match the observed longevity of the in vivo hydrogel platform. Multiple nanotechnology-based stabilizing agents will be employed. We will evaluate the glucose sensor performance with and without platinum nanospheres, catalase and other antioxidants over time. The ultimate objective is to achieve stable sensor response over 3 months with a maximum 5% loss in sensitivity over 1 month in accelerated aging conditions and H2O2 exposure.Refinement of fluorescent tissue-intergrating sensors promises to open a whole new sensing modality for diabetes management and health monitoring. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: Diabetes is a devastating and costly chronic disease affecting nearly 25 million people in the US alone and amounting to 200B in annual healthcare expenditures. Upon successful development of a novel, long-term, low cost, sensor in this SBIR Phase I, PROFUSA is poised to undergo further development of the prototype fluorescent sensor in pre-clinical and clinical models in order to demonstrate 90-day in vivo longevity and accuracy for inclusion in an artificial pancreas. Adoption of the PROFUSA CGM will motivate and enable diabetic patients to more tightly control their glucose levels without fear of severe glucose lows, and will reduce the diabetes disease burden on the healthcare system.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

14 SBIR/STTR records share this UEI (2011–2019). Reported award amounts total $16,353,356. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.