SBIR/STTR Research Award

Remote and non-invasive continuous cardiopulmonary monitoring using low-power FM

Award identifier 1bd5e3e222d4b257ff650befc4228779fdc377dc2bdab6a48b57809fceecc040Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$95,283

Program and phase

SBIR · Phase I

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
SYSTEMS MICRO TECHNOLOGIES
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2010-2
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): Proposed Research. Systems Micro Technologies (SMT) proposes to research the feasibility and to establish the mechanisms of applying a novel radar-based monitor for early detection of cardiopulmonary arrest (CA) by showing that SMT's micropower frequency-modulated radar (MFMR) can detect changes in the following four physiological variables: heart rate, respiratory rate, cardiac output and respiratory tidal volume. MFMR aims to enable continuous monitoring of these variables remotely, non-invasively and with no health risks to the patients. Problem/Opportunity. Cardiopulmonary arrest (CA), the leading proximate cause of in- hospital death in the US, can often be reversed or prevented with adequate intervention; however, in order to be effective, the life-saving activities have to start within minutes after CA. Two critical parameters that can reduce CA-mortality are expansion of the number of patients continuously monitored for the signs of CA and improving the reliability of monitoring by tracing more physiological variables. The innovative MFMR-based monitor proposed by SMT can achieve both of these effects by continuous remote and non-contact detection of changes in both the rates and output volumes of cardiac and respiratory activity of patients. MFMR's convenience and low operational cost will allow significant expansion of the types and numbers of patients subjected to continuous cardiopulmonary monitoring. Project Outline. SMT will build a prototype radar monitor using its currently existing MFMR unit (developed for non-medical purposes) as a starting point. The new prototype will be calibrated and undergo a series of performance tests. Once ready, the prototype will be used to validate the measurement of the four physiological variables of interest: absolute values of heart rate (HR) respiration rate (RR) and relative changes in cardiac ejection fraction (EF) and respiration tidal volume (Vt). Data processing and analysis algorithms will be developed to extract the values of these parameters from the radar reflection patterns. HR and EF monitoring will be validated using the Jaszczak beating heart phantom experiments. Simultaneous measurements of HR and RR, and detection of changes in Vt will be validated via patient studies at California Pacific Medical Center. Quantitative milestones for measurement of each of these parameters are defined. Success criteria formulated in terms of these milestones will have to be met in order to move to Phase 2 of the project. Benefits. If the feasibility for CA detection is confirmed, SMT will proceed to developing a marketable cardiopulmonary monitoring device for hospital and in-home use. The device will record data automatically and communicate it to the hospital patient alarm as well as communication system for further evaluation. The monitor will be used either as a single source of diagnostic information or as one of the components in a comprehensive patient evaluation when used in parallel with other methods. The proposed approach introduces major innovations that lead to three key benefits: The non-contact and convenient nature of SMT's radar allows it (1) to significantly expand the number of monitored patients, and (2) to reduce the time spent by caregivers; (3) SMT's radar can detect changes in cardiac output and respiration tidal volume, two important variables that are not commonly monitored now. This new diagnostic information can enable better understanding of the physiopathologies leading to CA. PUBLIC HEALTH RELEVANCE: Availability of reliable and convenient methods of continuous cardiopulmonary monitoring is critical for prevention of cardiac arrest mortality. Early detection of warning signs can prevent cardiopulmonary arrest deaths in many at-risk patients, both in the intensive care environment, in general hospital wards or at home. Remote, non-contact monitoring technology developed as the result of the proposed research will introduce a new paradigm in cardiopulmonary monitoring, potentially reducing the patient mortality from cardiopulmonary arrest and improving the patient's comfort while potentially even decreasing the cost of care.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.