SBIR/STTR Research Award

Synchronized Automated Valve CPR for Cardiac Arrest

Award identifier 7eee306c2542b810be7c9b0a491d73b2d4da2d9ba1154d51c1c2532a2e243b31Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$256,286

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
RESQSYSTEMS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA10-050
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): STD CPR by itself is inherently inefficient, in large part due to the lack of mechanical forces to draw blood into the heart during the chest wall recoil phase in order to refill the emptied chambers of the heart aftereach chest compression. Moreover, the coronary perfusion pressure is only marginally adequate as the pressure gradient between the aorta, the right atrium and left ventricle is far from optimal. When these inherent inefficiencies are combined with the multiple common errors associated with CPR performance (e.g. hyperventilation, incomplete chest wall depth and recoil) and the element of physical fatigue documented by even the fit and well-trained professional providers of CPR, it is clearly time for an industrial revolution in resuscitation and a better mechanical means to perform automated CPR. Based upon a combination of newly discovered multiple mechanisms to enhance circulation during CPR and the need to reduce human errors intrinsic to the performance of manual closed chest CPR, the goal of this SBIR phase 1 application is to develop a novel automated CPR device to further improve blood flow during cardiac arrest. The new automated device combines the concept of negative intrathoracic pressure (ITP) to enhance cardiac preload and lower resistance to brain blood flow by lowering intracranial pressure with that of providing intermittent, yet moderate, positive intrathoracic compression-phase pressures using oxygen insufflation to additionally enhance forward blood flow while maintaining oxygenation. The innovation of the new device lies in its design to optimize circulation of blood to the brain and other vital organs throughout the entire CPR cycle. Two core technologies will be combined in this 5-cycle automated CPR technology. They include: 1) a sternal active compression-decompression device to provide continuous chest compressions and full chest recoil, and 2) an electronic airway valve to both lower ITP during the chest decompression phase and provide passive oxygen insufflation after every other decompression to optimize circulation and provide ongoing hands-free ventilation. These two core technologies will be CPR-cycle synchronized to enhance cardiac preload, cardiac output, continuous blood flow to the brain, and oxygen delivery with a single automated device that does not rely on the quality of CPR provided by the caregiver. The specific aims of this research proposal are to: 1) Design and build a prototype non- invasive automated CPR device for thetreatment of cardiac arrest to provide optimal continuous circulation to the brain and other vital organs; 2) Demonstrate that use of the novel CPR device will significantly improve acute hemodynamics, vital organ blood flow, and 24-hour neurologically-intact survival when compared with STD CPR plus the ITD in a porcine model of cardiac arrest. This unique combination of non-invasive physiologically-based mechanisms has the potential to provide normal levels of circulation and ventilation during cardiac arrest which can significantly improve long-term neurologically-intact survival rates. If successful, this invention will result in saving gt10,000 more Americans each year from out of hospital cardiac arrest and a similar number of in-hospital survivors based upon the superior blood flow and the ability to perform prolonged CPR with normal physiology.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.