SBIR/STTR Research Award

QUADRATURE, RF COIL ARRAYS FOR MUSCULOSKELETAL MRI

Award identifier 4ac12e3261187ff5fbc8dba2b1fddf8741a04a6a9148b9a393ad04f00cd95bcaAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$0

Program and phase

SBIR · Phase I

Award year

2001

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ADVANCED IMAGING RESEARCH, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
MWJ5LUKXD3B7
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (Provided by Applicant): In Phase I, a RF coil array for high-resolution knee imaging was developed at 1.5T. Phantom tests and volunteer evaluations showed improved signal-to-noise of 24-28 percent over the industry standard. Phase II will involve optimizing the RF coil arrays based on a "new design," followed by extensive phantom and volunteer evaluations to achieve high signal-to-noise over the knee, foot and wrist joints of adults. A major technical focus is to improve the S/N of a NMR experiment by a factor of sqrt (2) over the industry standards. Potential clinical and research uses are to obtain reliable, reproducible high-resolution images needed to enhance diagnostic accuracy in possibly reduced scan times, reducing patient discomfort while increasing throughput in a MR scanner. This we believe will be of a substantial benefit to mankind. PROPOSED COMMERCIAL APPLICATION: Clinical applications include non-ionizing, non-invasive and a cost effective approach toward diagnosis of musculoskeletal diseases of the knee, foot and wrist when compared to the invasive arthrography. This project will provide improvements to MR phased array coil technology, including sequences and technique optimizations. If clinical value is demonstrated, MR systems based technology will find widespread applications in imaging the human musculosketal system.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

18 SBIR/STTR records share this UEI (1997–2024). Reported award amounts total $13,539,176. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Aeronautics and Space Administration

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.