SBIR/STTR Research Award

Magnetic Resonance Imaging Subsystem for Cardiac Ischemia Evaluation

Award identifier 557e9c8ba572f335c7d053c22330a5e03ac6c97362d5bb8b2e0cb1dea794411aAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,017,210

Program and phase

SBIR · Phase II

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
HeartVista, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
HACNWDAWXK53
Solicitation number
PHS2010-2
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): Cardiac magnetic resonance imaging has been shown to be one of the best technologies for the evaluation of cardiovascular pathologies. The broad application of this promising technology is expected to significantly improve the treatment of patients with heart disease in general and ischemic heart diseases in particular. However, widespread adoption of this beneficial technology has been held back by the lack of both software infrastructure and specific soft- ware sequences that take advantage of this infrastructure to provide a complete ischemic examination that can be performed rapidly in the clinical environment. The aim of this application is to develop a commercial robust cardiovascular subsystem that will enable the broad application of this technology to the clinical realm. Under previous NIH grant support through Stanford University, we have established real-time rapid imaging sequences for the assessment of wall motion and perfusion. We have also established the utility and accuracy of rapid coronary imaging sequences for the assessment of proximal coronary anatomy. Our goal in this proposal is to integrate these methods into a robust ischemic heart disease system to realize the clinical potential of cardiac MRI in the evaluation of coronary artery disease. During Phase I of this proposal, HeartVista developed and tested the alpha version of the cardiovascular software infrastructure that provides an integrated environment for rapid cardiovascular imaging. This package includes real-time evaluation of myocardial function under stress conditions, volumetric perfusion imaging, high resolution examination of myocardial viability in real-time and high-resolution examination of the proximal coronary anatomy. We installed the system at selected alpha sites and collected patient data. Generally, our methods concern obtaining adequate temporal resolution, spatial coverage, and contrast production for stress imaging using customized pulse sequences and hardware to reduce data acquisition time, 7 developing a underlying real-time imaging platform that allows the seamless real-time integration of receiver coil functions, pulse sequences, and post-processing and display that optimizes the workflow for studying patients with ischemia. This proposal focuses on developing and validating this combined examination to provide the clinician a robust and intuitive complete ischemic evaluation package that can be performed comfortably in less than 1 hour. During Phase II of this proposal, we will continue the development of our product based on the feedback obtained during Phase I and we will conduct a clinical study to demonstrate the non-inferiority of our product compared with conventional cardiovascular MRI examinations in robustness and diagnostic accuracy. PUBLIC HEALTH RELEVANCE: Ischemic heart disease remains the number one cause of mortality in the United States. Current diagnostic techniques have significant shortcomings that can result in inaccurate diagnoses. The reduced accuracy leads to a large number of unnecessary procedures. Given the enormous number of these procedures, even a modest improvement in diagnostic accuracy will have a large public-health impact. Cardiac magnetic resonance imaging has been shown to be one of the best technologies for the evaluation of cardiovascular pathologies. It is the only imaging modality that could provide all of the important parameters of ischemia evaluation in function, perfusion, viability and coronary anatomy in a single examination. The broad application of this promising technology is expected to significantly improve the treatment of patients with heart disease in general and ischemic heart diseases in particular. However, the adoption of this beneficial technology has been held back by the lack of both a software infrastructure and specific software sequences that take advantage of this infrastructure to provide a complete ischemic examination that can be performed rapidly in the clinical environment. The aim of this application is to develop a robust commercial cardiovascular subsystem that will enable the broad clinical application of this technology.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.