SBIR/STTR Research Award

An RF-Safe Interventional MRI Interface System

Award identifier b41e63393ea5f9bd01ce930336fe9eb8a250a21f95e1075bc28067ae772a30f9Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$220,619

Program and phase

SBIR · Phase I

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
HeartVista, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
HACNWDAWXK53
Solicitation number
PA11-096
Topic code
NIBIB

Research abstract

DESCRIPTION (provided by applicant): Less invasive surgical treatment is increasingly used because of less trauma, quicker recovery, and sometimes improved outcome. As the surgical exposure is reduced in these procedures, imaging has become increasingly important in the guidance of the procedure. While ultrasound and computed tomography can provide adequate visualization, MRI is the superior imaging modality due to its excellent soft tissue contrast. However, interventional MRI has been limited by the necessity of making each interventional device MR-safe. Since this process is frequently at odds with the functional design of the devices, the integration of magnetic resonance imaging as a common tool for intervention is severely limited. A MRI system designed to be device-safe would easily accommodate all the available interventional devices and eliminate one of the major bottlenecks of using MRI for the guidance of interventions. The aim of this application is to develop a robust commercial interventional MRI subsystem that will enable the application of this technology. Specifically, during Phase I of this proposal, HeartVista will demonstrate and test the feasibility of an RF-safe interventional MR interface subsystem that integrates into a commercialMR system. This subsystem will demonstrate a single transmit array element for providing safe localized excitation, a device transceiver interface demonstrating a low-power micro-coil excitation, and basic loopback control and real-time monitoring of RF safety. We expect to realize the basic infrastructure and functionality of this subsystem by the end of Phase I. Under previous NIH grant support through Stanford University and HeartVista Inc., we have established many of the systems needed for interventional MRI. These include high-fidelity real-time imaging, microcoil transceivers for real-time device tracking, and systems for parallel RF transmission. By the end of the Phase II period, we expect to provide 7 an advanced RF-safe interface to tightly monitor and control the RF deposition in the subject. 7 A state-of-the-art interventional imaging platform allowing control and data collection from a wide variety of interventional devices 7 a real-time imaging platform capable of orchestrating safety monitoring, device control, and simultaneous collection of real-time MR data. This proposal focuses on providing a device-safe MRI environment that will provide clinicians with the freedom to utilize the interventional devices that are most suited for theproblem at hand. PUBLIC HEALTH RELEVANCE: Less invasive surgical treatment is increasingly used because of less trauma, quicker recovery, and sometimes improved outcome. As the surgical exposure is reduced in these procedures, imaging has become increasingly important in the guidance of the procedure. While ultrasound and computed tomography can provide adequate visualization, MRI is the superior imaging modality due to its excellent soft tissue contrast. However, interventional MRI has been limitedby the necessity of making each interventional device MR-safe. Since this process is frequently at odds with the functional design of the devices, the integration of magnetic resonance imaging as a common tool for intervention is severely limited. A MRI system designed to be device-safe would easily accommodate all the available interventional devices and eliminate one of the major bottlenecks of using MRI for the guidance of interventions. The aim of this application is to develop a robust commercialinterventional MRI subsystem that will enable the application of this technology.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

7 SBIR/STTR records share this UEI (2007–2013). Reported award amounts total $8,137,264. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.