SBIR/STTR Research Award

Long-term Sensing in the Brain Using Sub-cellular Edge Electrode Arrays

Award identifier 9fc0c09e77a33ca8a95a1e2873159add3f94c1d568f7c7f74f05fdd54c45521aAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$221,890

Program and phase

STTR · Phase I

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Neuronexus Technologies, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
D5WZFBNJE5Y3
Solicitation number
PHS2010-2
Topic code
NINDS

Research abstract

DESCRIPTION (provided by applicant): Next generation neural probe technology must enable neuroscientists to bridge the gap between neurons and neuronal pools to fully understand the orchestrated 'temporal dynamics' of the brain. This will require high-density, stable recordings in longitudinal experiments. Similarly, next generation brain machine interfaces (BMI) must improve longevity and reliability of the recorded neural signals if translation of the research technology to the clinical realm is to be successful. Long-term signal degradation is widely believed to be directly related to cellular reactivity in the presence of the neural probe. The sub-cellular edge electrode array (or SEE probe) was designed to mitigate the cellular reactivity evident in conventional microelectrode designs and thereby address the longevity and stability issues of recording technology. The SEE design concept hypothesized that if a structural feature size is smaller than a reactive cell body (lt 7 lt m), the resulting cellular encapsulation would be mitigated by the prevention of cellular spreading or adhesion. This biomimetic concept resulted in the design of a conventional probe shank supporting a thin parylene platform only 5-5m thick. Histology results after 4 weeks show that cellular density surrounding the edge of the thin parylene structure had only a 129 percent increase relative to healthy tissue, versus a 425 percent increase around a conventional probe shank. This study proved that tissue encapsulation could be mitigated by a sub-cellular geometry and the appropriate electrode placement. Since this ground-breaking study, the SEE design concept has been further developed. New preliminary work has provided evidence of electrical stability using a parylene substrate, functional electrode arrays with a multi-sided edge geometry, and the ability to record neural activity in acute preparations. The SEE probe has tremendous promise for both research tools and clinical devices using recording technology. The proposed Phase I project will show the technical merit of the SEE probe through microfabrication and optimization (Aim 1), and providing long-term electrical validation (Aim 2). The scientific merit will be clearly demonstrated in chronic animal studies, which will use electrophysiology, electrode impedance, and histology to compare the edge electrodes to planar electrodes on the same device (Aim 3). NeuroNexus Technologies, a leading supplier of microfabricated, microscale neural probes, and the University of Michigan's Neural Engineering Laboratory, will collaborate to execute this important scientific and translational opportunity. PUBLIC HEALTH RELEVANCE: The primary objective of the proposed work is to develop and validate a microelectrode technology that has shown great promise in improving biocompatibility. This work will microfabricate a novel biomimetic design, the sub-cellular edge electrode array, and provide subsequent long-term validation in animal studies. Animal studies are expected to show improved electrophysiological recording quality, stability, and longevity. Such microelectrode technology will enable neuroscientists and clinicians to achieve long-term sensing in the brain, which would greatly improve our understanding of healthy brain function and offer new opportunities for those suffering from neurological disorders such as spinal cord injury, epilepsy, or ALS.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

8 SBIR/STTR records share this UEI (2006–2025). Reported award amounts total $5,286,554. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.