SBIR/STTR Research Award

Microfabricated Neural Probe for the Rapid Detection of Multiple Neurochemicals I

Award identifier bab3231fcdc80ce51c1e1f29a3ae3229f6307c7f073957774b1d18b8f242e5aeAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$385,932

Program and phase

SBIR · Phase I

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DIAGNOSTIC BIOCHIPS, INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
PF2EA6V5G9E3
Solicitation number
PA11-134
Topic code
NIAAA

Research abstract

DESCRIPTION (provided by applicant): The specific aim of this application is to test the feasibility of developing a long-lasting, implantable probe for rapid measurement of multiple neurochemicals in the brain. Currently, neuroscience research is limitedto three techniques for measuring the concentrations of neurochemicals in vivo; microdialysis to obtain average concentrations over a relatively long time period (5-20 minutes), enzyme-based biosensors to detect a single neurochemical every second over a relatively large spatial area (500 m length electrode), and carbon-fiber microelectrodes to detect dopamine with fast scan cyclic voltammetry (FSCV). A new tool is required for rapid detection of concentrations of multiple neurochemicals with spatial resolution on the cellular level. Such a tool would allow neuroscience researchers to ask new questions about the mechanisms behind disease states and behaviors, such as alcohol drinking. The proposed neural probe fulfills this need by detecting two neurochemicals every 4 seconds with 50 m spatial resolution. SB Microsystems has already developed a proprietary MEMS process for fabricating implantable, multi-site neural probes for studying the rat brain. Our existing probes have the feature size necessary for a 10-fold spatial resolution improvement over the available enzyme-based electrodes. The proposed probe will build on our existing platform by functionalizing the probe site surfaces with molecules for the detection of specific neurochemicals. Detection of multiple neurochemicals will be achieved by patterning different neurochemical- specific detection molecules onto adjacent probe sites. Our Phase I application will determine feasibility for commercialization of these probes by; 1) improving functionalizedprobe fabrication by adjusting aptamer molecule modifications, immobilization technique, and electrical signal detection to achieve the best possible sensitivity and time response, 2) developing a potentiostat circuit based for detection, 3) developing twoaptamer molecules; one that is specific, sensitive, and long-lasting for ethanol, and another for GABA. Next, we will 4) functionalize the probe to detect multiple analytes with the newly develop aptamers and 5) implant probes into mice for in vivo data collection. Success in this Phase I feasibility study will be determined by the accurate detection of physiologically relevant concentrations of ethanol and GABA by probes that are stable in vivo for 2 days. In Phase II, we plan to develop more aptamers that can be applied to our probes for the detection of more than 2 neurotransmitters. We will use principles of robust design to turn our prototype into a commercial product. The attached letters of support indicate that we may be able to sell a successful prototype from Phase I to neuroscience researchers. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: The proposed work will result in a tool that can be used to study the brain mechanisms behind disease states such as Parkinson's disease, and behaviors such as alcohol drinking. Through the rapid detection of multiple neurochemicals, this product can provide more detailed information than currently available neuroscience tools. SB Microsystems in an engineering services firm with experience in thefield of neuroscience tools and has the expertise required to produce robust, commercially viable implantable biosensors for neuroscience and clinical applications.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

6 SBIR/STTR records share this UEI (2013–2016). Reported award amounts total $4,275,879. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.