SBIR/STTR Research Award

Indwelling Biosensor for real time chemotherapeutic blood level monitoring

Award identifier 9f79c5a0c10c0acdbdf110f1efdccc5b2274ef33a69053b1dd8d1b0ed949403bAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,328,298

Program and phase

SBIR · Phase II

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DIAGNOSTIC BIOCHIPS, INC
Proposal award date
2016-04-01
Contract end date
2019-02-28
UEI
PF2EA6V5G9E3
Solicitation number
HL14-011
Topic code
NHLBI

Research abstract

DESCRIPTION provided by applicant The Specific Aim of this Phase II SBIR proposal is to develop a catheter based biosensor for monitoring chemotherapeutic blood levels during drug infusion This Phase II includes an IDE submission for clinical testing of our device The ability to monitor blood levels in real time will facilitate drug dosing within a narrow therapeutic range o minimize toxic side effects commonly cardiotoxicity and potentially maximize efficacy Our initial target therapeutic agent is doxorubicin Doxorubicin is a commonly used chemotherapeutic whose use is limited by dose related cardiotoxicity Swain et al Legha et al The proposed device allows for monitoring of doxorubicin peak blood levels and cumulative exposure which are correlated to heart tissue damage Desoize and Robert In part avoidance of cardiotoxicity is difficult due to inter individual pharmacokinetic variabiliy individuals receiving the same dose may have a five fold variation in area under curve AUC and peak blood concentrations Eksborg et al Additionally we will develop a similar imatinib sensor as part of this Phase II proposal as imatinib exposure is highly time dependent and plasma levels are correlated to toxicities Eechoute et al Widmer et al In Phase I R HL we demonstrated a catheter based biosensor for doxorubicin with a physiologically relevant dynamic range of nM uM with a stable readout in blood for andgt hours This device will be inserted into a patientandapos s vein a few minutes prior to a chemo infusion and will continuously measure drug levels prior to during and post infusion The burdensome existing method of blood draws and lab analysis to monitor patient drug blood levels generally precludes pharmacokinetically guided treatment in a non research setting Our device will make individual PK monitoring possible and affordable on a routine basis during drug treatment in most any setting Studies on pharmacokinetically guided treatment with fluorouracil have demonstrated improved objective response produced a trend towards higher survival rate and resulted in fewer grade toxicities in metastatic colorectal patients Gamelin et al Th proposed device will allow such monitoring to be routine In Phase I we showed that we could detect physiologically relevant doxorubicin concentrations for andgt hrs in blood using a prototype of a clinically implementable catheter design for IV fluid delivery In order to commercialize this product for clinical use we need to translate our device to a scalable FDA compliant manufacturing process and validate sensor functionality in vivo Success will be determined by demonstrating in vivo sensing for hours in devices manufactured by a process capable of producing units month at $ per device The proposed work will culminate in an FDA IDE submission PUBLIC HEALTH RELEVANCE The proposed work will result in a tool that can be used to monitor patient blood levels of chemotherapeutic drugs Through continuous real time data collection the proposed device will reduce toxicity from overdoses and inefficacy from under dosing Diagnostic Biochips already makes implantable biosensors for electrical detection and has the expertise required to produce robust commercially viable implantable biosensors for neuroscience and clinical applications

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

6 SBIR/STTR records share this UEI (2013–2016). Reported award amounts total $4,275,879. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.