SBIR/STTR Research Award

A percutaneous cardiac implant to treat mitral valve regurgitation

Award identifier 172cc700edd7679ca20640ec8c8cad2aaa61b60b2177fdfb1940f3c189c221edAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$179,124

Program and phase

SBIR · Phase I

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MIDDLE PEAK MEDICAL, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA12-088
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): Middle Peak Medical (MPM) is developing a novel percutaneous transcatheter technology, the MPM Mitral Leaflet Repair System, to eliminate mitral regurgitation (MR) caused by degeneration of the posterior leaflet. The System consists of the Coaptation Mesh (CM, an implant), a delivery catheter, and anchors. Given the minimally invasive route of implantation, the MPM Mitral Leaflet Repair System will be suitable for treatment of patients with moderate to severe MR who cannot or wish not be treated by surgery. Untreated MR can be debilitating, leading to poor exercise tolerance, shortness of breath, heart failure, and death. Of the 4 million U.S. patients diagnosed with MR, 600,000 fit established guidelines for operative treatment. Currently, open-heart surgery is the standard of care for these patients. Due to the significant morbidity, mortality and cost of the surgery, only about 50,000 of the sickest patients are treated annually. Nevertheless, hundreds of thousands of patients who are at high risk for open-heart surgery, or desire not to accept the morbidity and possible mortality associated with surgery, could benefit enormously from a less risky procedure. Our percutaneous approach involves placing a specially shaped synthetic mesh device, the CM, over the degenerate posterior leaflet complex using a transcatheter procedure performed by an invasive cardiologist in a cardiac cath lab. The CM, delivered through a small catheter, without surgery, will re-establish cooptation with the anterior leaflet, eliminating regurgitation. In this Phase I SBIR, we propose to provide preclinical data on the ability of the CM to reduce MR, with the following aims: Aim 1. Create an ovine model of mitral regurgitation. Our group has successfully tested this method in pilot studies. MR will be monitored using ventriculography, echocardiography, and hemodynamic measurements and a standard grading scale (0,1-4+). Milestone: create MR of at least 3+ in the setting of flail posterior leaflet cause by severing a chord to the leaflet edge. Aim 2. Demonstrate reduction of mitral regurgitation after surgical attachment of the CM. Following suture anchoring of the CM, we will monitor MR using ventriculography, echocardiography and hemodynamics. Reduction of MR will be measured immediately after CM implantation and one month post-op. Milestones: MR reduced to lt2+ immediately post-op and MR lt2+ maintained one month post implant, without damage to other parts of the heart or significant transmitral inflow pressure gradient. At the successful completion of this Phase I SBIR, we will be poised to begin a two-year Phase II SBIR, during which we will a) finalize the CM implant design; b) refine our percutaneous catheter delivery and anchoring system (developed using separate financing) to harmonize with the ultimate CM design; and c) perform such longer term chronic testing and in vitro studies as required to initiate an FDA-approvable Investigational Device Exemption (IDE) clinical trial. Our long- term goalis approval by the FDA for commercial sale within the US via the Premarket Approval process. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: Of the 4 million U.S. patients diagnosed with mitral regurgitation, 600,000 fit established guidelinesfor surgical repair and yet, given the significan risks and cost of open heart surgery, only about 50,000 of these patients seek an operation. Middle Peak Medical proposes a novel, less invasive approach to repairing mitral regurgitation employing a specially shaped synthetic mesh device to allow a damaged heart valve to properly close. The proposed device is designed to be implanted via a catheter threaded into the heart from a vein, rather than through open heart surgery, so that both the risk and the cost are dramatically decreased.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.