SBIR/STTR Research Award

High Resolution Scanning Magnetometry

Award identifier bd6ae5c6ab4fd6d79c67c0d2332eab1dc7dceb132c7f7db2258bc6f1abee76f7Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$150,043

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MOMENT TECHNOLOGIES LLC
Proposal award date
Not reported
Contract end date
Not reported
UEI
W4LKCW7QN664
Solicitation number
PA10-050
Topic code
NIBIB

Research abstract

DESCRIPTION (provided by applicant): In Phase I we propose to test the feasibility of developing a high-resolution scanning magnetometry for neuroscience based on a simple, but novel concept of primary source mirror (PRISM). The PRISM can be made with different designs, but in this project it will be an air-filled glass pipette with a small glass plate at the end with a tilt of 45o toward bottom. We claim that this mirror can be used to visualize the current distribution regardless of source orientations inan in vitro neuronal tissue with a spatial resolution as high as 10 5m when we complete the Phase II of this project. It has been well known that the magnetic field outside a conducting medium such as a bath filled with saline or the human head is solelydue to currents tangential to the conducting boundary. In the case of human head, magnetoencephalography (MEG) measures only the currents tangential, but not radial, to the brain-air boundary. In the case of a neuronal tissue in a bath, the magnetic fieldis solely due to currents tangential, but not perpendicular, to bath surface. This fundamental limitation has restricted the use of biomagnetometry. In Phase I we will use the PRISM in a physical phantom to test whether the PRISM will make the vertically oriented currents in a bath visible . When this mirror is submerged in a bath of physiological saline just above a neural tissue, it will produce the so- called secondary source oriented perpendicular to its surface when a population of neurons produces vertical or horizontal intracellular currents below the mirror. According to our simulation study, the horizontal component of the secondary source on the PRISM will make the vertical current visible to a magnetometer above the bath. We will compare the results with a realistic simulation study using a boundary element method to fully represent the experimental condition. We will further evaluate two important properties of this technique that may enable us to develop a high resolution scanning magnetometryin Phase II. We will test our claim that: (1) the spatial resolution primarily depends on the distance between the mirror and active neurons below, instead of the distance between the magnetic field sensing coils above the bath and the volume of active neurons, and (2) the spatial resolution is independent of the dection coil size (within reasonable limits). These results will enable us to develop a novel high-resolution scanning magnetometry in Phase II. PUBLIC HEALTH RELEVANCE: This simple, but novel invention will expand applications of magnetometry since it will enable us to obtain images of current distribution in biological tissues, containing currents in any directions with an unprecedent-ed level of spatial resolution. The scanning magnetometry should become an important new tool in bio-medical research in the area of direct high resolution imaging of electrical currents such as neural currents in biological tissues in vitro. This technique can be in principle applied to human MEG studies as well.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.