SBIR/STTR Research Award

Deep Brain Microelectrode Array for Functional Neurosurgery

Award identifier 262451768b4bfc7e7ff1a5664a52c9970265ee452b1d7d10d0424f26e79c8c1bAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$765,759

Program and phase

SBIR · Phase II

Award year

2007

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Neuronexus Technologies, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
D5WZFBNJE5Y3
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Deep brain stimulation (DBS) devices - 'brain pacemakers' - have recently emerged as an exciting novel neurotechnology for treating severe movement disorders, such as Parkinson's Disease and Essential Tremor. Accurate mapping of deep brain regions is necessary to obtain an optimal treatment of DBS with minimal risk to the patient. At present, electrophysiological mapping involves slowly advancing a single-channel microelectrode in small steps in order to record the neural activity in the region of the electrode tip. This process is tedious and time-consuming due to the serial nature of the procedure. The subject of this proposal, the Deep Brain Microelectrode Array (DBMA), is an innovative device that has multiple precisely placed sites along its length which permit simultaneous recording and stimulation at different depths in the brain, leading to more accurate and faster mapping. The DBMA is a modular device that consists of up to 18 recording sites positioned in a bi-linear arrangement such that multiple brain regions spanning 9mm or more may be monitored simultaneously. The basic components of the DBMA are the electrode array and the carrier. The electrode array is a microfabricated device based on polyimide with thin-film metal interconnects and electrode sites. The carrier is comprised of a clinical grade tungsten microelectrode and a polyimide tube. The device has been designed using FDA cleared materials and has the same form factor as a single-channel mapping microelectrode, essentially making it a drop-in replacement for the current device. Specific Aim 1 of Phase II will focus on extending the functionality of the recording array developed in Phase I by adding ring-shaped sites to the device that are suitable for macrostimulation. Manufacturing techniques will be optimized for high volume and clinical device production. Specific Aim 2 will develop a clinical grade multichannel data acquisition and stimulation system for use with the multimodal DBMA. The devices and instrumentation developed and bench tested in Aims 1 and 2 will be validated for use in mapping procedures in animals in Specific Aim 3. The outcome of the project will be a complete deep brain mapping system (i.e., mapping electrodes and instrumentation) ready for pre-clinical evaluation. An animal research version of the system will be ready for commercialization. NeuroNexus, Inc. is leading the project in collaboration with FHC, Inc., the University of Michigan and consultants from the Cleveland Clinic. This multi-disciplinary effort will result in a system positioned to become a key component in the planning and delivery of stereotactic interventions for neurological disorders, which will enable further optimization of current treatments and facilitate new treatments. Deep brain stimulation (DBS) devices - 'brain pacemakers' - have recently emerged as an exciting novel neurotechnology for treating severe movement disorders, such as Parkinson's Disease and Essential Tremor. Accurate targeting of deep brain regions is necessary to obtain an optimal treatment of DBS with minimal risk to the patient. This project will develop the necessary tools, an innovative deep brain mapping electrode and associated instrumentation, to increase the speed and accuracy of the mapping procedure.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

8 SBIR/STTR records share this UEI (2006–2025). Reported award amounts total $5,286,554. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.