SBIR/STTR Research Award

Motion-immune magnetic resonace imaging

Award identifier 0962f96d177528ecca49c7d945feb968abf79357438a24f1aef94ae05f3d3e8cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,147,390

Program and phase

SBIR · Phase II

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ROBIN MEDICAL INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
S38NM2MSMM14
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The long term aims of the proposed project are to improve image quality during magnetic resonance imaging (MRI) by elimination of motion artifacts. MRI is highly susceptible to motion during scan, and the elimination of the motion-induced artifacts will be based on real-time motion tracking of the imaged body and the application of the tracking data to re-align the gradients of the MRI scanner, in order to compensate for motion. This new technology can have significant i mpact on the health care system as motion artifacts degrade image quality in about 20% of performed studies and often require repetition of the study. Furthermore, new MRI modalities like functional and diffusion MRI are severely affected by motion, and th e elimination of motion artifacts will facilitate their clinical use. Following feasibility demonstration during Phase I of the project, we continue into Phase II. The specific aims of the project include: A - To modify the FDA-cleared EndoScout tracking s ystem that is clinically used in MRI-guided surgical interventions into a motion tracking system that can be interfaced with major types of diagnostic MRI scanners; B - To modify routine scan sequences of interest into motion-immune sequences by gradient r e-alignment using motion information supplied by the tracking system; C - To test the hypothesis that motion compensation through gradient re-alignment based on motion tracking can improve image quality in research and clinical MRI and is superior to curre ntly used methods for motion artifact elimination. The technology will be developed through a collaboration between Robin Medical, Inc., and the Massachusetts General Hospital: Robin Medical will develop a new generation of the EndoScout tracking system th at can become a standard components on diagnostic MRI scanners; Dr. Van der Kouwe at the Massachusetts General Hospital will modify various research and clinical scan sequences that will be needed during human tests of the system. Following the demonstrati on of successful motion artifact mitigation through technical testing with moving phantom, the system will be tested on volunteers and through on going research and clinical MRI human studies. PUBLIC HEALTH RELEVANCE: The proposed motion artifact mitigatio n technology may reduce healthcare costs associated with the common need to repeat MRI scans that are compromised by patient motion. In addition, as many diagnostic MRI scans are degraded by motion but not repeated due to the high cost of MRI, the new tech nology can improve the diagnostic yield of MRI by providing higher quality images. Furthermore, the motion-immune sequences may be used with pediatric patients and reduce the need for anesthesia in some age groups of this population.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

24 SBIR/STTR records share this UEI (1998–2020). Reported award amounts total $18,932,366. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.