SBIR/STTR Research Award

Low-Cost Electronic Nose for Groundwater Contaminants

Award identifier 744dcf91ae1a79070e7bba14011582ca0d43b117c8c2be6990669b340ad2c2baAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$991,563

Program and phase

SBIR · Phase II

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
SEACOAST SCIENCE, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
CM2UZ96ZVKS8
Solicitation number
PA10-050
Topic code
NIEHS

Research abstract

DESCRIPTION (provided by applicant): Several US agencies and regulators require low-cost chemical sensors for detecting and monitoring environmental clean-up, remediation, and decommissioning processes where groundwater may be contaminated. The sensors must be capable of detecting contaminants in the sub-surface groundwater and must be compatible with use in a range of environments. Most significantly, these customers require a low-cost alternative to its current expensive and labor intensive methods, namely using mobile laboratories. The project will result in the innovative use of low-cost sensor systems that will be capable of detecting and monitoring for dense non-aqueous phase liquids in the subsurface and groundwater, unattended, and in real- time fromwithin a push-probe, using a chemicapacitor array and miniature preconcentrator. The ultimate goal of this SBIR project is to provide the DOD, DOE, and other agencies with a method to map and track subsurface contamination plumes in real-time without requiring an operator. In Phase I, Seacoast successfully demonstrated the feasibility of using a microsensor array with a proprietary trap-and- purge preconcentrator to detect chlorinated solvents, specifically TCE, and TCA, at levels low enough to meet EPA mandated levels for drinking water. In Phase II Seacoast proposes to improve the selectivity and sensitivity of the system to better meet the needs identified by the Phase I consultant. The systems have MEMS microcapacitor sensor arrays that can monitor forleaks of toxic chemicals, contaminants from wastes, and changes in groundwater streams. A preconcentrator traps the contaminants and releases them to a microsensor array. These sensor arrays are filled with several chemoselective polymers whose dielectricpermittivity changes when exposed to different vapors, creating a fingerprint response for each chemical. In Phase II Seacoast will specifically develop new materials to improve the sensor array selectivity, 1) by using impedance spectroscopy to study the mechanisms by which the polymer-based sensors sorb the target chemicals, 2) by implementing pattern recognition algorithms to identify chemicals for the sensor responses, and 3) by designing new preconcentrator materials that can bind these chemicals more strongly. The most important application to public health and safety is unattended monitoring of drinking water, water treatment processes, and water sources. Potential markets include building chemical process monitoring and control, toxic vapor leak detection, industrial process control, and industrial health and safety. Transitioning the developed prototype to other markets where worker and public health, environmental health and regulatory compliance will be investigated to reduce the financial risksand broaden the acceptance of the technology. PUBLIC HEALTH RELEVANCE: This proposal describes a novel technology that specifically addresses the need for detecting groundwater contaminants and long-term monitoring of contaminated sites, by providing an unattended sensor system that tracks contamination in real-time and transmits contaminant concentrations. Such a system would be used in tandem with other methods, to provide comprehensive contamination management at DOE, DOD, and Superfund sites where ground and water clean-up projects are already underway. The proposed work will focus on detection of chlorinated hydrocarbons, which are described as among the most common pollutants in groundwater and soils at DOE sites.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

67 SBIR/STTR records share this UEI (2004–2025). Reported award amounts total $21,050,156. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Defense, Department of Health and Human Services, Environmental Protection Agency, Department of Agriculture, National Aeronautics and Space Administration, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.