SBIR/STTR Research Award

Rapid, Specific, Sensor System for Pathogens in Water

Award identifier 0a42b1db41a7963e555ece8ab8240723480ec301adf120d16aa92b95503cb386Awarding agency Environmental Protection Agency

Award amount

$69,046

Program and phase

SBIR · Phase I

Award year

2002

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Environmental Protection Agency
Branch
Not reported
Recipient company
TPL, INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
ZC4PPSM47QQ3
Solicitation number
Not reported
Topic code
Not reported

Research abstract

There is an important need for a water-monitoring technology that is capable of detecting a wide range of microbial and viral pathogens and their toxins. TPL, Inc., proposes an instrument system that could be used both in the laboratory or in the field for analyzing water quality for a wide range of contaminants, including microbial pathogens, Cryptosporidium, and viral pathogens. The sensor system will be based on new technology under development by TPL and its research partners at the University of New Mexico. That technology will use protein molecules as probes for microbial and viral targets. The protein molecules used provide the system with an extremely high level of specificity and sensitivity for the pathogens of interest. The probe proteins will be covalently bound to a micromachined sensor (or array of sensors), making the sensor durable and reusable. During operation, a stream of water or a water sample will be introduced to a test chamber in the water analysis instrument, where the aqueous sample comes in direct contact with the sensor. The analysis system will perform the desired analysis and output data concerning the type and concentration of analyte (e.g., pathogen) detected. The system does not rely on delicate laser detection systems or low levels of fluorescent light. The sensor will utilize an extremely sensitive microelectronic gravimetric device, known as an acoustic plate mode (APM) device. The proposed sensor can measure surface adsorption in either liquid or gas phase with picogram sensitivity and millisecond response time. High-speed digitization and digital signal processing techniques will be used to deconvolute the data contained in the APM acoustic wave modes generated by the sensor.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

220 SBIR/STTR records share this UEI (1984–2022). Reported award amounts total $49,867,963. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Energy, National Science Foundation, National Aeronautics and Space Administration, Department of Health and Human Services, Nuclear Regulatory Commission

Agency intelligence

Environmental Protection Agency

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.