SBIR/STTR Research Award
A Percutaneous Ultrasound-Guided Catheter for Organ and Vascular Access
Award amount
$133,446Program and phase
STTR · Phase IAward year
2011Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- INNOSCION, LLC
- Proposal award date
- Not reported
- Contract end date
- Not reported
- UEI
- Not reported
- Solicitation number
- PA10-051
- Topic code
- NHLBI
Research abstract
DESCRIPTION (provided by applicant): Safe and reliable access to major blood vessels and internal organs will be beneficial to patients with cardiovascular disease and cancer. An interventional catheter with ultrasound imaging capability will be developedto enable image-guided access to blood vessels and internal organs. Computer simulations and preliminary data using a transducer similar to that proposed for the study suggest a high likelihood of success. This Phase 1 STTR proposal seeks to develop a working prototype of the device and demonstrate feasibility of the device in its exemplary clinical uses in in-vitro gel phantoms. We will build a high frequency, small aperture forward viewing ultrasound transducer, characterize it and test it with various iterations of plastic multi-lumen catheters in a standardized gel phantom. In particular, studies will seek to demonstrate the device ability to track the device tip in real-time and guide it to specific targets in the gel phantom. This phase 1 proposal willprovide proof of concept and select the best candidate prototype for phase 2 studies. No such device is currently available in the market and the successful development of a clinically implementable device has immense commercial potential by its ability to contribute significantly to the advancement and expansion of minimally invasive medical procedures. PUBLIC HEALTH RELEVANCE: This Phase 1 STTR proposal seeks to develop a working prototype of an ultrasound guided, interventional device and to demonstrate feasibility of the device in particular exemplary clinical uses in in-vitro gel phantoms.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- DUCTUS ARTERIOSUS STENT TO IMPROVE CONGENITAL HEART DEFECT MORTALITY
- Head Up CPR and Aortic Occlusion to Improve Survival after Refractory Cardiac Arrest
- Free-Breathing Dynamic Cardiopulmonary Function Imaging System to use with Xenon MRI
- The Next Wave of Asthma Therapeutics
- Bearingless flux reversal motor for neonatal and pediatric extracorporeal life support applications