SBIR/STTR Research Award

Optimization of Human Head MRI and MRS Using High Order Shim Insert

Award identifier c356226ba135ad2b639d74803983c5b5aa8b51ed99ed11ae9e5b7261516e9bd0Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$176,028

Program and phase

STTR · Phase I

Award year

2009

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
RESONANCE RESEARCH INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
WVS2DE4Q4T95
Solicitation number
PHS2009-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Multiple studies in MR provide irrefutable evidence that the use of high order shims for controlling magnetic field inhomogeneity brings significant improvement to image quality, particularly at high fields and in challenging shimming regions, such as in the inferior frontal and temporal lobes of the human head. MRI manufacturers however, have been very resistant to the idea of improving the performance of shims in high field scanners even though it has been demonstrated that the performance of the conventional 2nd order shims available in all 3T and 7T systems is unsatisfactory. The cost and complexity of the upgrade to higher order shim capability, the necessary improvement in shimming software and the applications development create serious barriers for rectifying this situation and in bringing about an improvement. The only commercial 7T scanner with 3rd order shims is manufactured by Philips but in many applications it lacks some software capabilities for rendering the shims useful. The goal of this proposal is to develop a high order (3rd, 4th and 5th) shim insert for head MR that overcomes the cost and complexity of integrating those shims into the magnet bore, and renders a highly practical arrangement for efficient shimming of the human head. An unequivocal demonstration of significant improvements in performance using 3rd order shims has been documented in the preliminary results leading to this proposal. We are now leading the development of the practical implementation of the 4th order shims. The novel aspect of our development will be the construction of a high order resistive shim coil set which has strength and performance sufficient to null the 4th order spherical harmonic field components present in challenging regions of the brain and which can also be retrofitted inside an existing gradient coil. In particular, neurological applications require extended shimming performance. For such a purpose, by using a highly optimized head RF coil, enough space can be saved in a whole body scanner to mount an insert capable of delivering the 3rd and 4th order shims at high strength, while not compromising the accessibility for other applications. Demonstrating the safety and efficacy of the proposed in-bore shim coil set will make possible the commercial use of this technology in the form of an upgrade that can be applied to a large number of commercial scanners that presently lack this capability. PUBLIC HEALTH RELEVANCE: Magnetic resonance imaging (MRI) and spectroscopy (MRS) are the leading techniques for obtaining high-quality images and metabolic profiles of intact healthy and diseased human tissues. Unfortunately, tissue susceptibility induced spatial variations of magnetic field can severely degrade the quality of MRI and MRS data, to the extent that distinction between normal and diseased areas may be compromised. The current project focuses on developing and implementing novel technology that can be used in new scanners or retrofitted to existing scanners thereby leading to greatly increased quality of MR data with consequent benefit to public health.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

9 SBIR/STTR records share this UEI (1992–2024). Reported award amounts total $3,168,539. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.