SBIR/STTR Research Award

Fully Compensated Dynamic Shim System for In Vivo MRI and MRS

Award identifier dbdba2c4d41aaf23ec6af320be0a9ec52da4549580108e0ad54d204c565f56afAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$748,196

Program and phase

STTR · Phase II

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
RESONANCE RESEARCH INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
WVS2DE4Q4T95
Solicitation number
PA08-051
Topic code
NCRR

Research abstract

DESCRIPTION (provided by applicant): Functional MRI, diffusion MRI and MR spectroscopy and spectroscopic imaging have great potential for the study and diagnosis of disease and injury, and guiding surgical therapy. All of these methods benefit greatly fromthe added sensitivity, resolution and contrast from high field strength magnets (3T and above). However, the advantages of higher magnetic fields have not been fully realized due to the increasingly confounding effects of magnetic field inhomogeneity (MFI) caused by magnetic susceptibility differences between air and tissue. MFI leads to signal loss and spatial distortion in MRI and loss in spectral resolution and sensitivity in MRS. The loss of reliability due to these artifacts is a major reason why these techniques have not seen wide use in clinical applications. Current methods of magnetic field homogenization (i.e. shimming) work well on small volumes but are inadequate over larger objects, like the entire human brain. Over the last decade, the MR group at Yale University has developed the technique of dynamic shim updating (DSU) which allows greatly improved magnetic field homogeneity over extended regions. DSU divides a global 3D problem into a number of slices over which adequate magnetic field homogeneity can be achieved. Dynamically updating the pre-determined slice shims in sync with the multi-slice MRI sequence ensures optimal homogeneity for all slices. Following a successful completion of the Phase I STTR grant, the current Phase II applicationcontinues the work towards commercialization of DSU. Specifically, DSU hardware will be further improved and combined with professional software to automatically set up the unit. Since DSU is significantly more complicated than regular shimming, additionalsoftware will be provided for the every day operation of the unit by standard MR users. Since MFI affects almost all facets of in vivo NMR, the successful commercialization of DSU will have major impacts on the clinical application of MRI and MRS and canthus be labeled as highly significant. PUBLIC HEALTH RELEVANCE: Magnetic resonance imaging (MRI) and spectroscopy (MRS) are the leading techniques to obtain high-quality images and metabolic profiles of intact human tissues in health and disease. Unfortunately, spatial variations in magnetic field strength introduced by the sample can severely degrade the quality of MRI and MRS data, such that distinction of normal from diseased tissues may be compromised. Current technology is not able to completely cancelthe spatial magnetic field variations. The current project focuses on the development of novel technology that can significantly reduce spatial magnetic field variations, thus leading to greatly increased MRI and MRS data quality.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

9 SBIR/STTR records share this UEI (1992–2024). Reported award amounts total $3,168,539. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.