SBIR/STTR Research Award

cvSim+CCTA to noninvasively assess hemodynamic significance of coronary lesions

Award identifier 8f99bd627f5906bc0922a0c317ff218ee5a603167b30447958e1ab50d7694defAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$338,268

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
HEARTFLOW, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA10-050
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): Cardiovascular Simulation, Inc has developed software, cvSim-3DTM, to augment coronary computed tomographic angiography (CCTA) with patient-specific blood flow data and provide a noninvasive alternative to diagnostic cardiac catheterization for assessing the hemodynamic significance of coronary artery lesions. We estimate that, even accounting for the costs of CCTA and cvSim-3DTM, this would save the U.S. health care system at least 6 billion annually and result in better care for patients. Of the patients who get diagnostic cardiac catheterization (the 2nd most common medical procedure) in the U.S. each year, approximately 50% of them do not have hemodynamically significant lesions. Recent clinical data from the DEFER and FAME studies indicate that patients without hemodynamically significant lesions should be treated with medical therapy, not angioplasty and stenting. CCTA has provided an unprecedented ability to noninvasively visualize the coronary arteries and identify patients with coronary artery disease, but is insufficient for determining whether patients with intermediate lesions would benefit from percutaneous coronary interventions (PCI). Fundamentally, CCTA provides exquisite information on coronary anatomy andmorphology of disease, but lacks physiologic information on coronary blood flow. We have developed methods to quantify blood flow in patient-specific models of the human coronary arteries and predict the hemodynamic significance of coronary lesions at rest and during physiologic challenge. This approach involves creating a three-dimensional finite element model of the aortic root and coronary arteries from CCTA data, coupling a lumped parameter heart model at the aortic inlet and lumped parameter models atthe aortic and coronary outlet boundaries and simulating pulsatile blood flow and pressure using custom computational fluid dynamics methods. We believe that our software, used in conjunction with CCTA, will be able to reliably identify the lesions that are not hemodynamically significant, and therefore dramatically reduce the number of diagnostic cardiac catheterizations that are performed each year. The purpose of Phase I of this SBIR grant is to conduct a pilot clinical correlation study to demonstrateand evaluate our methods for modeling coronary blood flow. PUBLIC HEALTH RELEVANCE: Cardiovascular Simulation, Inc's has developed software, cvSim-3DTM, to simulate coronary blood flow in patient-specific models created from coronary computed tomographic angiography (CCTA) data and predict hemodynamic significance of lesions. This software will be used to model coronary blood flow from CCTA data in 30 patients, and then will be evaluated by comparing predictions for each patient to pressure measurements made during diagnostic cardiac catheterization.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.