SBIR/STTR Research Award
cvSim+CCTA to noninvasively assess hemodynamic significance of coronary lesions
Award amount
$338,268Program and phase
SBIR · Phase IAward year
2011Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- HEARTFLOW, INC.
- Proposal award date
- Not reported
- Contract end date
- Not reported
- UEI
- Not reported
- Solicitation number
- PA10-050
- Topic code
- NHLBI
Research abstract
DESCRIPTION (provided by applicant): Cardiovascular Simulation, Inc has developed software, cvSim-3DTM, to augment coronary computed tomographic angiography (CCTA) with patient-specific blood flow data and provide a noninvasive alternative to diagnostic cardiac catheterization for assessing the hemodynamic significance of coronary artery lesions. We estimate that, even accounting for the costs of CCTA and cvSim-3DTM, this would save the U.S. health care system at least 6 billion annually and result in better care for patients. Of the patients who get diagnostic cardiac catheterization (the 2nd most common medical procedure) in the U.S. each year, approximately 50% of them do not have hemodynamically significant lesions. Recent clinical data from the DEFER and FAME studies indicate that patients without hemodynamically significant lesions should be treated with medical therapy, not angioplasty and stenting. CCTA has provided an unprecedented ability to noninvasively visualize the coronary arteries and identify patients with coronary artery disease, but is insufficient for determining whether patients with intermediate lesions would benefit from percutaneous coronary interventions (PCI). Fundamentally, CCTA provides exquisite information on coronary anatomy andmorphology of disease, but lacks physiologic information on coronary blood flow. We have developed methods to quantify blood flow in patient-specific models of the human coronary arteries and predict the hemodynamic significance of coronary lesions at rest and during physiologic challenge. This approach involves creating a three-dimensional finite element model of the aortic root and coronary arteries from CCTA data, coupling a lumped parameter heart model at the aortic inlet and lumped parameter models atthe aortic and coronary outlet boundaries and simulating pulsatile blood flow and pressure using custom computational fluid dynamics methods. We believe that our software, used in conjunction with CCTA, will be able to reliably identify the lesions that are not hemodynamically significant, and therefore dramatically reduce the number of diagnostic cardiac catheterizations that are performed each year. The purpose of Phase I of this SBIR grant is to conduct a pilot clinical correlation study to demonstrateand evaluate our methods for modeling coronary blood flow. PUBLIC HEALTH RELEVANCE: Cardiovascular Simulation, Inc's has developed software, cvSim-3DTM, to simulate coronary blood flow in patient-specific models created from coronary computed tomographic angiography (CCTA) data and predict hemodynamic significance of lesions. This software will be used to model coronary blood flow from CCTA data in 30 patients, and then will be evaluated by comparing predictions for each patient to pressure measurements made during diagnostic cardiac catheterization.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- DUCTUS ARTERIOSUS STENT TO IMPROVE CONGENITAL HEART DEFECT MORTALITY
- Head Up CPR and Aortic Occlusion to Improve Survival after Refractory Cardiac Arrest
- Free-Breathing Dynamic Cardiopulmonary Function Imaging System to use with Xenon MRI
- The Next Wave of Asthma Therapeutics
- Bearingless flux reversal motor for neonatal and pediatric extracorporeal life support applications