SBIR/STTR Research Award
12-lead MRI-Compatible ECG for physiological monitoring and scanner synchronizati
Award amount
$191,624Program and phase
SBIR · Phase IAward year
2011Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- E-TROLZ, Inc.
- Proposal award date
- Not reported
- Contract end date
- Not reported
- UEI
- Not reported
- Solicitation number
- PA10-050
- Topic code
- NHLBI
Research abstract
DESCRIPTION (provided by applicant): This SBIR project aims to develop an MRI-compatible 12-lead ECG system. Such a system will provide greatly improved physiological monitoring inside the MRI, which is important for imaging severely ill patients (stroke, spine, patients with ischemic histories), and is also key to future MRI-guided interventions and surgeries. Current MRI-compatible ECG monitoring is limited to 4-closely spaced electrodes, and is intended mainly for outpatient imaging. In addition, gradient-induction (VGrad) and magneto-hydro-dynamic (VMHD) artifacts distort the waveform, not allowing for reliable acute-ischemia detection. The 12-lead system will remove these artifacts and provide clean ECG (ECGreal) traces, similar to those measured outside MRI. Our Specific Aims are: Aim #1: MR compatible 12-lead ECG acquisition and transmission We will develop a 3 Tesla MR-compatible ECG acquisition system using 10 MRI-compatible electrodes positioned at standard torso locations, with coaxial-cable transmission lines carrying ECG signals from the electrodes to the MRI PUBLIC HEALTH RELEVANCE: This study is relevant due to difficulties in recording accurate ECGs during MRI scanning of severely ill and critical care patients, such as traumaor ischemic patients, which leads to their exclusion from imaging. However, MRI is an excellent modality to detect acute stroke1, acute spinal injury2, and post- infarction damage3, so improved ECG would lead to improved care. Moreover, 12-lead ECG is thestandard-of-care for detecting acute ischemia4, but ischemia indicators frequently are masked by MRI
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- DUCTUS ARTERIOSUS STENT TO IMPROVE CONGENITAL HEART DEFECT MORTALITY
- Head Up CPR and Aortic Occlusion to Improve Survival after Refractory Cardiac Arrest
- Free-Breathing Dynamic Cardiopulmonary Function Imaging System to use with Xenon MRI
- The Next Wave of Asthma Therapeutics
- Bearingless flux reversal motor for neonatal and pediatric extracorporeal life support applications