SBIR/STTR Research Award

A FIBER OPTIC AQUEOUS PHASE TRICHLOROETHYLENE SENSING INSTRUMENT

Award identifier c40c274d229f6a18fe8f7c2319f98e59c6fb6097e0d69c1e0405264d6e3d1710Awarding agency Department of Defense · Air Force

Award amount

$360,504

Program and phase

SBIR · Phase II

Award year

1993

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Defense
Branch
Air Force
Recipient company
EIC LABORATORIES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
QXCJLSJ7NPC3
Solicitation number
Not reported
Topic code
Not reported

Research abstract

THE PURPOSE OF THIS PROGRAM IS TO DEVELOP A REAL-TIME CHEMICAL SENSING INSTRUMENT FOR DETECTING AND MONITORING OF CHLORINATED ORGANIC SOLVENT CONTAMINANTS, PARTICULARLY TRICHLOROETHYLENE (TCE). THE PROPOSED WORK IS BASED ON THE PRINCIPLE OF COMBINING SPECTROSCOPIC, ELECTROCHEMICAL AND FIBER OPTIC TECHNIQUES. SPECTRO-ELECTROCHEMICAL FIBER OPTIC SENSING (SEFOS) IS, IN PRINCIPLE, A GENERIC TECHNIQUE WHICH CAN BE ADAPTED TO MANY DIFFERENT SENSING APPLICATIONS. THE INCORPORATION OF SPECTROSCOPIC DETECTION, SUCH AS FLUORESCENCE, SHOULD ENABLE MANOMOLAR LIMITS (I.E., PPB LEVELS OR LESS), UNLIKE ELECTROCHEMICAL METHODS WHICH ARE GENERALLY LIMITED BY BACKGROUND CURRENTS DUE TO IMPURITIES AND NON-FARADAIC PROCESSES. THE TECHNIQUE HAS AN ADVANTAGE OVER CURRENT FIBER OPTIC CHEMICAL SENSING METHODS IN THAT THE SENSING ONLY TAKES PLACE WHEN THE ELECTRODE DEVICE IS TURNED ON. THIS ENABLES LONG-TERM MONITORING OF A WELL/SITE TO BE ACCOMPLISHED WITH ONLY ONE SEFOS PROBE. THE GOAL OF THE PHASE I PROGRAM IS TO TEST THE FEASIBILITY OF USING SPECTRO-ELECTROCHEMICAL METHODS FOR THE DETECTION OF THE CHLORINATED ORGANIC SOLVENT, TCE, IN THE RANGE OF AQUEOUS CONCENTRATIONS FROM 5 PPB TO THE SOLUBILITY LIMIT. THE GOAL OF THE PHASE II PROGRAM IS TO DEVELOP AND TEST A FIBER OPTIC BASED PROTOTYPE FIELD PORTABLE INSTRUMENT FOR THE FIELD SCREENING/IN SITU MONITORING OF TCE AND OTHER CHLORINATED ORGANIC SOLVENT CONTAMINATION.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

392 SBIR/STTR records share this UEI (1983–2025). Reported award amounts total $89,797,365. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Health and Human Services, National Aeronautics and Space Administration, Department of Energy, National Science Foundation, Environmental Protection Agency

Agency intelligence

Department of Defense

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.