SBIR/STTR Research Award

Magnetic Drive Mechanism for VF Doppler Smart Sensor

Award identifier aa78e76bd4501af084a97f11330306c4edb83989d986c0cfaa9b4274a86dc291Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$101,323

Program and phase

STTR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ARBOR ULTRASOUND TECHNOLOGIES, LLC
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA10-051
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): Prior to dialysis vascular access failure (thrombosis), blood flow decreases from a baseline value to zero over some unknown time period. While the natural history and variation of flow prior to access failure is poorlyunderstood, it is known that customary monthly access flow monitoring is not frequent enough in many clinical settings for adequate prediction and prevention of an impending thrombosis. The effectiveness of access surveillance depends on the frequency andaccuracy with which monitoring can be performed. Therefore, the VF Doppler Automated Smart Sensor is being developed for continuous real-time flow monitoring during dialysis. We hypothesize that an active motion compensation/tracking control system utilizing feedback technology can be used to produce a commercially viable point-of-care Doppler based blood-flow monitoring device suitable for VF Doppler smart sensor (compact, low-cost, continuous) monitoring for dialysis and for general flow applications forvascular disease. Our research has determined that introducing active transducer motion compensation with the associated feedback mechanisms will allow for signal optimization improving blood flow measurement accuracy that has not been previously realized. Adding this active transducer drive capability introduces significant advantages for a commercializable device enabling practical clinical viability. Not only will it enhance the accuracy of the diagnostic flow measurement, but it also will allow measurements for broader vascular flow applications outside the dialysis setting. Therefore, this proposal will develop and evaluate a real-time transducer motion compensation system based on a magnetic drive mechanism for the VF (volume flow) Doppler smart sensor with feedback control. This proposal builds upon extensive work and will reduce the risk for successful commercial translation of this NIH sponsored technology. PUBLIC HEALTH RELEVANCE: This proposal will integrate a feedback control system and magnetic actuator into a compact, low-cost Doppler automated smart sensor for longitudinal operator-independent blood flow monitoring. This device will improve care and reduce cost for dialysis patients and patients with peripheral arterial disease.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.