SBIR/STTR Research Award

Portable device for monitoring water balance in elderly

Award identifier 9c4cbbc4fba6b0056960cf58f331301b35f4b14b1bf2f64eb1f546f13df6b457Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$269,255

Program and phase

SBIR · Phase I

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
3DT HOLDINGS, LLC
Proposal award date
Not reported
Contract end date
Not reported
UEI
E527XPXM1CJ7
Solicitation number
PA12-088
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): Transseptal (TS) access for left heart procedures is an important and rapidly growing space for diagnostics and therapy delivery with an expected total of over 10 million U.S. patients. In the U.S. and/or Europe, TS access procedures are used for atrial fibrillation (AF) ablation, left atrial appendage (LAA) closure, patent foramen ovale (PFO) closure, and treatment of mitral valve regurgitation (MR). For the latter, treatment of severe MR can be accomplished through TSaccess and the placement of a clip (MitraClip or MC) on the mitral valve. Catheter positioning for MC placement has been challenging even for the most experienced interventionalist cardiologists (ICs) and has led to long procedure times with significant x-ray exposure. The initial TS access entry point into the left side of the heart s the key factor for MC placement. TS access procedures have not significantly changed since early reports by Ross in 1959 ( drag and drop technique) and many challenges stillexist with this method including difficulty with: catheter localization, catheter stabilization, and the risk f atrial wall or aortic puncture. While the drag and drop technique provides an optimal inferior septal access point for ablation procedures, the MC procedure requires a more superior/posterior puncture site due to the multiple turns required by the catheter for final clip placement. While this superior/posterior position can be located with echocardiography, the constant movement of the heart and the thin and slippery nature of the fossa ovalis (FO) make standard TS access punctures unpredictable. Access that is too high or too low relative to the mitral valve can make implantation of the MC virtually impossible thus requiring device removal, TSre-puncture, and device re-advancement. Thus, initial localization on the FO with subsequent stabilization prior to and during TS access is critical for MC procedures to limit implant times and x-ray exposure. In this proposal, we will validate the abilityof a novel, deflectable transseptal access catheter (TSAC) that utilizes vacuum suction technology to provide improved catheter localization and stabilization, easier puncture of the FO, and thus leading to decreased TS and MC procedural and x-ray exposure times. To accomplish this goal, we will assess both the safety and the ability of the TSAC to reduce procedure and x-ray exposure times for delivery of MC relative to traditional means for TS access in human cadavers with heart failure and in chronic heart failure swine with MR. This proposal addresses a clinically significant problem with applications that can reach beyond treatment of MR to multiple TS left heart procedures. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: The ability to achieve adequate localization and stabilization of the left atrium during atrial transseptal puncture is important for numerous procedures, including the delivery of mitral clips for the treatment of mitral valve regurgitation. The purpose of this Phase I SBIR is to validate the ability of a novel, low profile suction catheter to provide safe and stable access across the atrial septum for decreased procedural and fluoroscopic exposure time and to improve therapy delivery.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

29 SBIR/STTR records share this UEI (2010–2025). Reported award amounts total $17,062,625. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.