SBIR/STTR Research Award

ER:YAG LASER LENS EMULSIFICATION

Award identifier 346ceca8c57b472081b3794bfe01bb406d7b607c716421081c3cbb5381223317Awarding agency Department of Health and Human Services

Award amount

$750,000

Program and phase

SBIR · Phase II

Award year

1995

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
INTRALASE CORPORATION
Proposal award date
Not reported
Contract end date
Not reported
UEI
H521NUVJGFC3
Solicitation number
Not reported
Topic code
Not reported

Research abstract

THE OBJECTIVE OF THIS RESEARCH IS TO DEVELOP AN INNOVATIVE TECHNIQUE AND ASSOCIATED INSTRUMENTATION FOR ANTERIOR CAPSULOTOMY AND LENS EMULSIFICATION WHICH ALLOWS THE MAJORITY OF OPTHALMOLOGISTS TO PERFORM THESE PROCEDURES WITH GREATER SAFETY AND EFFICACY. THE PHASE I STUDY FOCUSES ON ER:YAG LASER LENS EMULSIFICATION. THE FOUR OBJECTIVES OF THIS STUDY ARE: TO IDENTIFY THE ER:AG PULSE INDUCED ACOUSTIC EFFECT IN LENS EMULSIFICATION, TO ESTABLISH THE OPTIMAL LASER DOSIMETRY, TO EVALUATE THROUGH HISTOLOGICAL TECNIQUES THE PRESENCE OR LACK THEREOF OF ADVERSE EFFECTS TO ADJACENT STRUCTURES IN THE EYE, AND TO DESIGN A CLINICALLY EFFICACIOUS FLEXIBLE DELIVERY SYSTEM FOR LENS EMULSIFICATION. THIS BASIC RESEARCH IS THE FOUNDATION FOR FURTHER IN VIVO TESTING OF THE TECHNIQUE AND INSTRUMENTATION DURING THE PHASE II STUDY. THE RESULTS FROM THE IN VITRO AND IN VIVO STUDIES WILL ALLOW TIMELY DEVELOPMENT AND OPTIMIZATION OF THE OPTHALMIC INSTRUMENTATION. PREMIER LASER SYSTEMS HAS ALREADY CLINICALLY DEMONSTRATED THE ADVANTAGES OF THE ER:YAG LASER AND FLEXIBLE FIBEROPTIC DELIVERY IN PERFORMING A SMOOTH CIRCULAR ANTERIOR CAPSULOTOMY ON 10 PATIENTS. THE SUBSEQUENT PROCEDURE FOR INTRAOCULAR LENS REPLACEMENT INVOLVES THE EMULSIFICATION AND ASPIRATION OF THE OPAQUE LENS. IN PURSUING LASER LENS EMULSIFICATION, OUR PRELIMINARY DATA ARE VARIABLE BUT ILLUSTRATE THAT THE ER:YAG LASER HAS THE POTENTIAL TO BOTH ABLATE AND ACOUSTICALLY EMULSIFY ALL GRADES OF LENSES INCLUDING DENSE GRADE THREE AND FOUR LENSES, WHICH ARE NOT AMENABLE TO PHACOEMULSIFICATION.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

8 SBIR/STTR records share this UEI (1992–2002). Reported award amounts total $2,304,888. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.