SBIR/STTR Research Award

Rapid-scanning optical-resolution photoacoustic microscopy

Award identifier 4ea4381c00845acd5b2dd6de9466285663fd340c743ea62399b74e1b3bc271ffAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$100,000

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MICRO PHOTO ACOUSTICS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA10-050
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): We propose to develop rapid-scanning optical-resolution photoacoustic microscopy (OR-PAM), which is capable of label- free imaging of non-fluorescent optical absorbers. Optical absorption contrast is highly desirable for microvascular imaging and characterization because of the presence of endogenous strongly light-absorbing hemoglobin. The proposed imaging system can provide a 5-micron lateral resolution, a 15-micron axial resolution, a 1.2-mmimaging depth, and a 30-Hz B-scan frame rate. The following specific aims are proposed. Aim 1. System design and implementation: The proposed rapid-scanning OR-PAM is expected to outperform the current version in imaging speed by a factor of 10. Nearly diffraction-limited optical focusing is employed to achieve the lateral resolution. Absorption of the focused light produced photoacoustic waves due to thermoelastic expansion. Detection of the photoacoustic waves using a high-frequency focused ultrasonic transducer measures the internal light absorption distribution and hence provides a 3D mapping of the optical structure. OR-PAM is able to measure optical absorption with a relative sensitivity of 100%, the theoretical limit of any linear-effectimaging methods. Rapid scanning of the dual optical-ultrasonic foci is required to achieve a high imaging rate. Aim 2. Testing the imaging system in phantoms and living mice: The proposed OR-PAM system will be tested with phantoms and living mice to quantify the maximum imaging depth, spatial resolution, SNR, and the frame rate for B- scan imaging. PUBLIC HEALTH RELEVANCE: Microcirculation, the distal functional unit of the cardiovascular system, provides exchange sites for gases, nutrients, metabolic wastes, and thermal energy between the blood and the tissues. Pathologic microcirculation reflects the breakdown of homeostasis in organisms, which ultimately leads to tissue inviability. Therefore, the proposedin vivo microvascular imaging and characterization is of significant physiological, pathophysiological, and clinical importance.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.