SBIR/STTR Research Award

Low energy ventricular defibrillator

Award identifier 3cb241397c74cdc90d87f51acb65ee58822a723bd3bf76fdcfb3f65c87457374Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$250,742

Program and phase

STTR · Phase I

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
CARDIALEN, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
UD4RRRFL7RV6
Solicitation number
PA11-097
Topic code
NHLBI

Research abstract

DESCRIPTION (provided by applicant): Sudden cardiac death is a major cause of death around the world, with approximately 400,000 sudden deaths per year in the United States, more than are attributed to lung cancer, breast cancer, or AIDS. It is often caused by ventricular fibrillation (VF) and ventricular tachycardia (VT). VF is the most frequent mechanism of sudden death. Implantable cardiac defibrillators (ICDs) have become the standard of care for patients at risk for sudden death following two decades of advancement in ICD therapy. The most common strategy for terminating VF is with a large electric shock by ICDs. Despite the proven efficacy of ICDs in saving lives, at least three major issues have been linked with their high voltage (HV) shocks. First,high voltage shocks produce substantial pain, which is often associated with anxiety, fear, depression, and reduced quality of life. Secondly, an estimated 20 percent of patients with ICDs may experience inappropriate shocks within three years of implant in response to a non-lethal arrhythmia or electrical noise within the device. In the primary prevention era, inappropriate shocks are even more troublesome, since appropriate shocks are decreasing in incidence; shocks are being delivered to patients with nohistory of symptomatic arrhythmias. Thirdly, shocks have been associated with an increased risk of heart failure and death. A new report by Sweeney, et al clearly demonstrated that shocked patients have substantially higher ventricular arrhythmia episodeburden and poorer survival compared with anti-tachycardia pacing-only-treated patients. The virtual electrode polarization (VEP) concept has been proposed as a mechanism sustaining atrial fibrillation (AF) and demonstrated in experimental optical mapping of transmembrane potential studies in vitro and in vivo. Recent canine results have revealed that multiple-stage therapy (MST) significantly lowers the energy required for atrial defibrillation. Specifically, the three-stage therapy significantly lowersthe energy for cardioversion of AF by application of three different stages of therapy, which we mechanistically relate to the: (1) unpinning of wave fronts that maintain AF, (2) prevent repinning of wave fronts to tissue heterogeneities such as scar, and(3) annihilation of remaining wave fronts. We hypothesize that internal ventricular defibrillation will be effective using a mult-stage algorithm that will require much less energy level than the current single biphasic shock. To evaluate this novel method, we propose to develop an efficient external defibrillation system based on the VEP concept incorporating two different engineering approaches; 1) variable pulse modulation and 2) single FET power amplifier system. We will then test in an acute canine study to compare performance with a single fixed vector versus a variable vector. It is anticipated that the proposed new study will provide fundamentally important insights into the hypothesis that multiple phased low-energy shocks can safely achieve internal ventricular defibrillation. We expect the study is a big step forward from the VEP and unpinning theory to ventricular defibrillator clinical development. If the enhanced system is effective and safe for ventricular defibrillation, it should advancecommercial product development of low-energy multiple pulse implantable defibrillator devices and will also encourage a higher percentage of eligible patients to consider this life-saving treatment. PUBLIC HEALTH RELEVANCE: Sudden cardiac death is a major cause of death around the world, with approximately 400,000 sudden deaths per year in the United States. Ventricular fibrillation (VF) is the most frequent cause. The most common strategy for terminating VF is with a single, large, biphasic electric shock by an implantable cardiac defibrillator (ICD). Despite ther effectiveness, there have been increasing concerns with current ICD design, due to cardiac tissue damage likely induced by high voltage shocks, pain caused by inappropriate shocks, and short battery life. Currently, only about 1/3 of the eligible patient population has a defibrillato implanted. Redesign and optimization of shock waveforms is critical for developing a low-energy defibrillator delivering multistage therapy and incorporatingvariable pulse-shaped waveforms that will be more acceptable to patients and clinicians. The current global market for ICDs is approximately 6.6 billion and is projected to grow to 7.8 billion by 2014, offering opportunities to break into this market with disruptive technology.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

4 SBIR/STTR records share this UEI (2011–2020). Reported award amounts total $5,242,905. Reported amounts are not federal obligations.

Phases: Phase I, Phase II – Direct to Phase II, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.