SBIR/STTR Research Award

Low-cost Large-area High-Sensitivity X-ray Panel Detector for Digital Mammography

Award identifier c892603a1798f9d3a0871989d142fe47ebff035fb7b09c9f0fbaea94f7896844Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$100,000

Program and phase

SBIR · Phase I

Award year

2010

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DXRAY, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2010-2
Topic code
NIBIB

Research abstract

DESCRIPTION (provided by applicant): In this Phase I proposal we will develop a cost-effective large-area high-sensitivity x-ray panel detector for digital mammography. This direct-conversion x-ray detector will dramatically improve the capability for cost- effective high-performance mammography. By growing polycrystalline CZT (cadmium zinc telluride) films directly onto custom CMOS readouts, we will create large area panels with high resolution and high sensitivity. These panels will provide cost-effective, high-performance detectors for many other x-ray imaging applications including general radiography, fluoroscopy, and x-ray CT. We will leverage our existing expertise in polycrystalline film growth, solid-state x-ray detector physics, and x-ray readout ASIC design to produce CZT (cadmium zinc telluride) films grown directly onto customized CMOS readouts. Recently, academic research groups in Korea and Japan have investigated the potential for polycrystalline CZT films grown directly onto readouts to create x-ray imaging panel detectors. These studies have shown that relatively low substrate temperatures can be maintained during the film growth, enabling direct growth onto readouts such as thin-film transistor arrays and CMOS devices. The films produced have shown good x-ray detection properties. We propose to extend this work in the U.S., using our own experience in mercuric iodide polycrystalline film growth for x-ray imaging detectors and our experience in designing and producing CMOS-based readouts compatible with direct growth of mercuric iodide films. In this Phase I we will develop the film growth apparatus and processes necessary for successful polycrystalline CZT film growth on ITO-coated glass slides and we will measure the x-ray detection performance. This will substantially reduce the risk for Phase II. In previous work, we have designed, fabricated, and coated large area (10 cm x 10 cm) imaging charge-integrating CMOS readout chips which are chemically compatible with mercuric iodide. In this work, we will adapt them for compatibility with the CZT film growth process. The readouts have 30 5m pixel grids, enabling high-resolution imaging, and 8 parallel outputs which produce an 8 frames per second readout speed for the 10 Mpixel device. In Phase II, the CZT-coated CMOS readouts will be tested for x-ray imaging characteristics. Most digital mammography systems have spatial resolutions limited by their use of indirect detectors - scintillators coupled to photodiode arrays. A few recent systems are based on amorphous selenium, a direct detector. However, even these systems are limited to pixel sizes of about 70-100 5m. The CMOS readouts which will be coated in Phase II incorporate 30 5m pixel grids, giving mammography and other x-ray imaging modalities access to higher spatial resolutions. The devices will also be cost-effective due to the approach of growing CZT films directly onto readout arrays. We will widely market the device as an OEM component to mammography system manufacturers. PUBLIC HEALTH RELEVANCE: We will grow a high-sensitivity detector material, cadmium zinc telluride (CZT), directly onto CMOS technology megapixel readouts. This will achieve significant breakthroughs in x-ray imaging panel detector price and performance. Mammography will benefit due to the improved spatial resolution and reduced cost from this unique combination of detector material and readout.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.