SBIR/STTR Research Award

Fast Neutron Imaging Scintillator with Low Sensitivity to Gamma Radiation

Award identifier 69948bf8806c7cf8bfafe87db978ce39090e1450e3286c37f8f2fbb3c10f8321Awarding agency Department of Energy

Award amount

$100,000

Program and phase

SBIR · Phase I

Award year

2006

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
RADIATION MONITORING DEVICES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
SCKQA85YU4U4
Solicitation number
DE-FG01-05ER05-28
Topic code
25

Research abstract

Neutron crystallography compliments x-ray crystallography in its ability to precisely locate hydrogen and light atoms in various materials. This information is important for biological applications (for example, monitoring protein dynamics), and material research and security applications (for example, explosives detection, etc.). However, the detectors available for scattered neutron radiation are still inadequate. The ideal detector would provide fast response, high spatial resolution, high neutron efficiency, low gamma sensitivity, and large detection area at reasonable cost. This project will develop a detector, based on a finely-structured plastic scintillator coupled to a state-of-the-art digital readout, that meets the above requirements The structure of the scintillator's body will enhance light channeling to the digital optical detector, promoting very high spatial resolution. The scintillator will be loaded with neutron sensitive elements, such as B and Gd. In Phase I, a 5 x 5 cm2 prototype sensor will be fabricated and evaluated using a novel CCD-based detector and a PSPMT at neutron beam facilities. The effectiveness of the technology will be demonstrated by neutron radiographic imaging of various test phantoms. The efficiency, time response, and spatial resolution of the detector will be measured. Commercial Applications and Other Benefits as described by the awardee: The modified scintillator should find widespread in neutron radiography and neutron crystallography. The detector, along with its components (e.g., the structured plastic scintillator) could be employed at any neutron source facility and would advance basic research in material science, protein mechanisms, and drug design. Further applications could be found in non-destructive testing and secuity scanning at entry ports and strategic facilities

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

930 SBIR/STTR records share this UEI (1983–2026). Reported award amounts total $346,950,619. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Energy, Department of Health and Human Services, Department of Defense, National Aeronautics and Space Administration, National Science Foundation, Department of Homeland Security

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.