SBIR/STTR Research Award

VENTSAFE™ Life Saving Ventilation for the Treatment of ARDS

Award identifier a2d0a41beb3a74155ea264df66b155665028f1390cb800572c75459877532e61Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$579,289

Program and phase

SBIR · Phase I

Award year

2024

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Liberandum Technologies, Inc.
Proposal award date
2024-09-01
Contract end date
2025-10-31
UEI
EREVZ11HCL36
Solicitation number
PA23-230
Topic code
NHLBI

Research abstract

The goal of this Phase 1 SBIR project is to develop and test a bidirectional synchronous flow-controlled ventilation system to improve oxygenation and ventilation in Acute Respiratory Distress Syndrome (ARDS). Respiratory failure is a significant cause of mortality, leading to one million deaths annually worldwide1. Respiratory pandemics are frequent and lead to profound mortality with conventional therapy alone. Conventional ventilation (CV) induces and potentiates alveolar trauma through numerous well-established mechanisms of ventilator-induced-lung-injury (VILI) including: volutrauma, barotrauma, and atelectatic-trauma. We propose to develop a ventilation system that has a lower potential for trauma and reduced need for sedation and paralysis. VENTSAFE™ has the potential to provide gentle lung ventilation without the damaging effects of CV. Instead of artificially expanding and collapsing the lung, the system performs gas exchange at tightly controlled, near-static pressures. VENTSAFE™ technology overcomes the shortcomings of existing high frequency ventilation systems by employing a bidirectional synchronous flow-controlled ventilation system. Our device allows for much higher frequencies than existing technologies creating a near-static low amplitude pressure wave. Using a rudimentary device and a physical test system, along with results from computational fluid dynamics (CFD) airflow analysis, we have preliminary data demonstrating that our system is able to deliver bidirectional synchronous flow-controlled, ventilation from the Endotracheal tube inlet at a near-static pressure while circumventing trauma that is common from conventional ventilators. This should translate into lower sedation requirements and eliminate risk of breath stacking. We will test the hypothesis that a bidirectional synchronous flow-controlled ventilation system will demonstrate improved oxygenation and ventilation in an ARDS lung model. To test this hypothesis, we will conduct the following specific aims: Aim 1. Perform CFD analysis. Milestone: Design demonstrates equivalent or improved ability to oxygenate and ventilate (simulated expired CO2 and O2) compared to CV forces in a CFD lung model. Aim 2. Develop a robust experimental prototype. Milestone: Device demonstrates ability to maintain and adjust mean airway pressure with the ability to effectively clear CO2 on a physical lung model. Aim 3. Preclinical and benchtop test of VentSafe™ ventilation system in both native and damaged lung models compared to conventional ventilation. Milestone: Demonstrate improved oxygenation (>5mmHG PaO2 increase) and improved ventilation (>5mmHG PaCO2 decrease) with arterial blood gas analysis (ABG) at specific time intervals compared to convention ventilation system (p<0.05). Acceptable lung tissue histology. At the conclusion of this Phase 1 SBIR we seek to have a validated, robust experimental prototype that has demonstrated improved ability to oxygenate and ventilate in ARDS compared to conventional ventilation. In Phase 2 we intend to develop a scalable, market- ready prototype for statistically significant modeling to justify moving to the clinic.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.