SBIR/STTR Research Award

Bench-top Reader and Aptamer-based Assay for Rapid, High-sensitivity Drug/Opiate Detection

Award identifier f702022c4900b1028c25be17415f01a3529a794d45185bc62bc6ac84595a95e9Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,497,700

Program and phase

SBIR · Phase II

Award year

2024

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
BASE PAIR BIOTECHNOLOGIES INC
Proposal award date
2024-08-01
Contract end date
2026-07-31
UEI
FFAKKLCKBNN7
Solicitation number
PA22-176
Topic code
NIBIB

Research abstract

Project Summary/Abstract The United States is experiencing an epidemic of unprecedented scope with heroin use resurging and a troubling pervasive increase in abuse of prescription opioids such as fentanyl, fentanyl derivatives, methadone, oxycodone and hydrocodone. More than 6 out of 10 drug overdoses are now opioid-related, resulting in ~90 deaths/day and a more than $75B/year economic impact. Additionally, there is a rapidly expanding need to detect numerous other small molecules such as therapeutic agents, in the home or potential WMDs like sarin and toxic pesticides in the remote or field setting. To develop a general purpose tool to address such detection, we propose to refine our compensated interferometric reader (CIR) and further develop a unique and efficient, matrix insensitive, assay methodology to address the need for high sensitivity, rapid testing of opioids, therapeutics and environmental contaminants. Our efforts will produce a first of its kind bench- top (and field-compatible) CIR and user-friendly (turn-key) assay system for the detection and/or quantification at ng/mL-pg/mL sensitivity of a wide range of targets including opiates, small molecule drugs, and organophosphorus pesticides. The assay based on a near-surface assay (NSA) embodiment, consists of three-steps; 1) collect sample (dilute if needed), 2) fill the pre- coated capillary and 3) read the ‘sample’ with CIR. Results for drug or metabolite detection in urine by CIR is predicted to be <300 pg/mL sensitivity for the fentanyl family, a >10-1000-fold improvement over the best lateral flow tests (LFT)1 and the current cutoff for standard drug tests. The non-invasive, nanoliter volume, high specificity urine or buffer-diluent assays will facilitate rapid field-based detection of environmental samples, seized illicit narcotics, counterfeit drugs and organophosphorus nerve agents (OPNA). Similar minimally invasive assays are feasible with minute amounts of finger-stick blood. The novel methodology is enabled by the marriage of three patented technologies, a multiplex-SELEX approach for aptamer selection, an aptamer-probe assay, and CIR to quantify the target. Phase I and Phase II Aims proposed here are designed to enable rapid translation/commercialization of the proposed technology.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

15 SBIR/STTR records share this UEI (2013–2024). Reported award amounts total $6,350,488. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Agriculture

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.