SBIR/STTR Research Award

Low Size, Weight, and Power, High Gain 2D Material-Based Detectors for Mass Spectrometers

Award identifier 8790aeb18c2daefc5f784c270c3c939060779f5f128e3ee60b5500a0917278cdAwarding agency National Aeronautics and Space Administration

Award amount

$899,978

Program and phase

SBIR · Phase II

Award year

2023

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
National Aeronautics and Space Administration
Branch
Not reported
Recipient company
GUARDION INC
Proposal award date
2023-05-12
Contract end date
2025-05-11
UEI
V31JYMV2LJS7
Solicitation number
SBIR_22_P2
Topic code
S13

Research abstract

This project will develop low power, high intrinsic amplification 2D material ion detectors shown in Phase I to work as low mass, low volume detectors for mass spectrometry from the feasibility stage to working examples. Guardionrsquo;s proposed solution is to eliminate the need of high voltage electron multipliers utilizing patented 2D material-based ion detectors that provide intrinsic charge to current amplification values ranging between 1E6-1E9 A/C, and only require an operating bias of 0.1V. It further distinguishes between positive and negative ions, and works from atmospheric pressure through ultra high vacuum. Unlike conventional methods of detection used in mass spectrometry, our sensors will exploit a low-bias intrinsic quantum gain mechanism in nanomaterials to amplify the signal from trace amounts of ions. This eliminates the need for external amplification, eliminates high voltage requirements, and significantly reduces power consumption. We have shown that replacing sensors in a commercial residual gas analyzer with these detectors can sense trace gasses. We propose to modify two existing mass filter systems, one residual gas analyzer and one ion trap mass spectrometer with our detector assembly and demonstrate comparable performance to state of the art detectors while using 10,000x less voltage. We will then demonstrate sensor response to mass range, sampling rate, charge state, and ion energy. Finally, we will generate a demonstration and report assessing the sensor performance, benefits, and limitations with suggestions on what types of mass spec and missions would be benefitted for sensor adoption. nbsp;

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

9 SBIR/STTR records share this UEI (2018–2025). Reported award amounts total $2,818,994. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: National Aeronautics and Space Administration, Department of Defense, National Science Foundation

Agency intelligence

National Aeronautics and Space Administration

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.