SBIR/STTR Research Award

Shim System for Removing ICD Artifacts from Patient Cardiac MR Images

Award identifier dc4efcf2765804bc6738ed646f89d998b7c221b246271bc0373bca2d7361a9edAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$309,942

Program and phase

STTR · Phase I

Award year

2022

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MIRTECH INC.
Proposal award date
2022-09-15
Contract end date
2023-08-31
UEI
EF8MM8LVY6F8
Solicitation number
PA21-262
Topic code
NHLBI

Research abstract

Project Abstract1.4 million people in the US (2021) have implanted cardioverter-defibrillators (ICDs) of which ~50% will require an MRI scan in their lifetime. All ICDs generate large artifacts in MRI such as signal-voids in cardiac MR (cMR) images, which frequently occur in important pathological (infarcted) regions. Reliable diagnosis of ventricular tachycardia, premature ventricular contraction and myocarditis using cMR is therefore prevented, as well as MR-guided therapy of these potentially life-threatening diseases. The scanner’s own shim coils cannot correct these large inhomogeneities, so powerful dedicated resistive shim coils are required.It is proposed that a Cardiac Shim System (CSS), consisting of a mechanical frame for accurate shim-coil placement, a shim coil, a programmable power supply, electromagnetic filtering circuits, shim-coil placement optimization software, and system-use protocols can be used to precisely reduce artifacts in a user-determined region of the heart. The innovative CSS design does not interact with, and is not acted upon by, the rf coils and the gradient coils of the scanner, maintaining the scanner’s specified performance. Furthermore, the magnetic forces acting upon the CSS are balanced, permitting the shim coil to be moved freely within the MRI scanner bore and maximizing patient safety.Aim 1 of this Phase I STTR project is to develop a commercial prototype (V2), based upon the initial proof- of-concept system (V1), to be used on a Siemens 1.5T MRI scanner at JHU. This includes refinements in shim coil design, software reconstruction, protocol development, and the development of a motorized positioning system. In Aim 2, it is proposed, to test this novel system quantitatively using 5 infarcted swine and 6 human volunteers to demonstrate CSS effectiveness in performing cMR safely using standard cardiac MRI protocols such as LGE and cine. Future Phase 2 efforts will pursue clinical testing to prepare for submission to the FDA for regulatory clearance.Project Narrative 1.4M patients (US) have implantable Cardiac Defibrillators (ICDs) that create large artifacts in cardiac MR images, which frequently occur in important pathological regions of the heart preventing reliable diagnosis of various heart diseases. We propose to build and test a Cardiac Shim System to reduce these artifacts in a user determined region of the heart. Testing and validation will be performed in phantoms, infarcted swine, and human volunteers to demonstrate the effectiveness of the device.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

2 SBIR/STTR records share this UEI (2012–2022). Reported award amounts total $809,068. Reported amounts are not federal obligations.

Phases: Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.