Explore This Research Award in CaptureIQ
Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.
Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- MIRTECH INC.
- Proposal award date
- 2022-09-15
- Contract end date
- 2023-08-31
- UEI
- EF8MM8LVY6F8
- Solicitation number
- PA21-262
- Topic code
- NHLBI
Research abstract
Project Abstract1.4 million people in the US (2021) have implanted cardioverter-defibrillators (ICDs) of which ~50% will
require an MRI scan in their lifetime. All ICDs generate large artifacts in MRI such as signal-voids in cardiac MR
(cMR) images, which frequently occur in important pathological (infarcted) regions. Reliable diagnosis of
ventricular tachycardia, premature ventricular contraction and myocarditis using cMR is therefore prevented, as
well as MR-guided therapy of these potentially life-threatening diseases. The scanner’s own shim coils cannot
correct these large inhomogeneities, so powerful dedicated resistive shim coils are required.It is proposed that a Cardiac Shim System (CSS), consisting of a mechanical frame for accurate shim-coil
placement, a shim coil, a programmable power supply, electromagnetic filtering circuits, shim-coil placement
optimization software, and system-use protocols can be used to precisely reduce artifacts in a user-determined
region of the heart. The innovative CSS design does not interact with, and is not acted upon by, the rf coils and
the gradient coils of the scanner, maintaining the scanner’s specified performance. Furthermore, the magnetic
forces acting upon the CSS are balanced, permitting the shim coil to be moved freely within the MRI scanner
bore and maximizing patient safety.Aim 1 of this Phase I STTR project is to develop a commercial prototype (V2), based upon the initial proof-
of-concept system (V1), to be used on a Siemens 1.5T MRI scanner at JHU. This includes refinements in shim
coil design, software reconstruction, protocol development, and the development of a motorized positioning
system. In Aim 2, it is proposed, to test this novel system quantitatively using 5 infarcted swine and 6 human
volunteers to demonstrate CSS effectiveness in performing cMR safely using standard cardiac MRI protocols
such as LGE and cine. Future Phase 2 efforts will pursue clinical testing to prepare for submission to the FDA
for regulatory clearance.Project Narrative
1.4M patients (US) have implantable Cardiac Defibrillators (ICDs) that create large artifacts in cardiac MR
images, which frequently occur in important pathological regions of the heart preventing reliable diagnosis of
various heart diseases. We propose to build and test a Cardiac Shim System to reduce these artifacts
in a user determined region of the heart. Testing and validation will be performed in phantoms,
infarcted swine, and human volunteers to demonstrate the effectiveness of the device.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
Research funding history
2 SBIR/STTR records share this UEI (2012–2022). Reported award amounts total $809,068. Reported amounts are not federal obligations.
Phases: Phase I
Agencies: Department of Health and Human Services
Agency intelligence
Department of Health and Human Services
Back to SBIR/STTR Research Awards