SBIR/STTR Research Award
Leaflet sparing transcatheter aortic valve equipped with IVUS-guided delivery system.
Award amount
$349,309Program and phase
SBIR · Phase IAward year
2022Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- VALVENTION INC
- Proposal award date
- 2022-08-01
- Contract end date
- 2023-04-30
- UEI
- MKPFRMVLTND9
- Solicitation number
- PA20-260
- Topic code
- NHLBI
Research abstract
PROJECT SUMMARY/ABSTRACT
Transcatheter aortic valve replacement (TAVR) is an essential alternative to surgical aortic valve replacement
(SAVR) in elderly patients with aortic valve stenosis. At the current pace, TAVR procedures are expected to
increase twofold from ~163,000 in 2020 to ~289,000 in 2025, and the number of patients with severe aortic
stenosis is anticipated to rise to 3.5M by 2050.
Given the predominately older patients in the intermediate and high-risk TAVR groups, vascular injury with
bleeding is still a major complication (6% to 8% incidence), and an unmet clinical need, which must be avoided
by next-generation devices with lower profiles. However, lowering the profile of the current TAVR delivery
systems with smaller sheath size comes at the cost of a more aggressive stent-crimp. Stent-induced traumatic
injury to the leaflets after transcatheter valve implantation has been scientifically and clinically established.
Considering that the stress exerted by each thin stent's strut is equal to the crimping force divided by strut's
surface pressing over the leaflets, the magnitude of stent-crimping stress will be enormous since the strut
surface is very small. Leaflet damage in TAVR due to current practice of stent crimping provokes a calcium
influx that leads to calcium crystal nucleation and collagen fiber disruption, which predispose to leaflet
degeneration, and early valve failure, as presented by leaflet thickening, stiffening and apparent calcification.
FoldaValve™ Technology, a novel self-expandable 14-Fr transfemoral TAVR system which uses a
fundamentally different concept to spare leaflets from stent-crimping, has been developed by Kheradvar Lab to
address TAVR clinical unmet needs by reducing the delivery profile while avoiding aggressive stent-crimp of
the leaflets. Due to its unique folding mechanism, FoldaValve™ attains the smallest delivery size at true 14-Fr,
implantable using a 15-Fr sheath. In addition to its small delivery profile, given that aggressive stent-crimping is
considered a triggering factor for early structural deterioration and subclinical leaflet thrombosis by many
investigators, FoldaValve should contribute to TAVR durability. Moreover, FoldaValve™ is uniquely equipped
with an intravascular ultrasound (IVUS)-guided delivery system (Ingenuity™), which reduces the need for
Fluoroscopy during implantation and minimizes radiation to both patient and physician. Ingenuity™ uniquely
allows repositioning in six degrees-of-freedom even when the valve is fully implanted and allows complete
intraprocedural valve retrieval, which has not yet practiced in other TAVR systems.
This Phase I project will first test the hypothesis that FoldaValve's inverse folding mechanism under the sheath
protects the valve's structural integrity and improve its durability compared to the current TAVR generation's
stent-crimping, and then will assess FoldaValve's chronic performance according to ISO 5840-3:2021:
Specific Aim 1: Establish the protective effects of FoldaValve's inverse folding mechanism under the sheath in
comparison with the traditional stent-crimping as practiced by other TAVR systems.
Specific Aim 2: Assess FoldaValve's chronic performance (20 weeks) in standard ovine model considering
paravalvular leakage, leaflet thrombosis, and calcification according to ISO 5840-3:2021.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- DUCTUS ARTERIOSUS STENT TO IMPROVE CONGENITAL HEART DEFECT MORTALITY
- Head Up CPR and Aortic Occlusion to Improve Survival after Refractory Cardiac Arrest
- Free-Breathing Dynamic Cardiopulmonary Function Imaging System to use with Xenon MRI
- The Next Wave of Asthma Therapeutics
- Bearingless flux reversal motor for neonatal and pediatric extracorporeal life support applications