Development of a Highly Accurate Wrist/Ankle-Mount Non-invasive Blood Pressure Monitor for Neonatal Patients

Award identifier e6efe165f7abe8331b33dc8c20523b7f34b1d1dfee0f0bd9e4c99255c2fefb03Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$355,000

Program and phase

SBIR · Phase I

Award year

2022

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
JB HEALTHTECH, INC.
Proposal award date
2022-06-01
Contract end date
2024-05-31
UEI
untlkkmsn8g9
Solicitation number
PAR22-073
Topic code
NHLBI

Research abstract

SUMMARY/ABSTRACT More than 340,000 neonates are admitted to the neonatal intensive care unit (NICU) each year in the United States. Monitoring arterial blood pressure (BP) for them, particularly preterm low-birthweight newborns, can be challenging. The oscillometric (OSC) brachial cuff is much less accurate in neonates than in adults because it derives systolic and diastolic pressures using population-based ratios. With lower BP, neonates as a group are statistically underrepresented in these ratios, thus their BP measurements tend to be erroneous. The standard method for neonatal BP monitoring is via the umbilical arterial catheter (UAC). However, UAC fails to work for approximately 10% of patients when both umbilical arteries are damaged or regressed after birth. For these patients, there is no alternative available. UAC also carries significant risks, including thrombosis, hematomas, infections, and even death. To address this unmet clinical need for neonatal BP monitoring, JB HealthTech, Inc. (JBH) is developing a highly accurate non-invasive BP monitor neoBPTM that operates in 3 modes. Its continuous mode provides high-fidelity arterial BP waveforms similar to UAC, to derive arterial pressures, respiration rate, and a suite of hemodynamic parameters. Its intermittent mode gives a convenient BP snapshot and heart rate, similar to OSC. Its periodic mode runs at predefined running/resting time intervals for any clinical needs in between. neoBP is based on a volume clamp (VC) technology, which is advantageous over other technologies, such as statistical modeling where neonates are underrepresented, less accurate devices with airbags only, and cuffless devices depending on calibration with UAC or OSC for every use. Using a novel closed-form theoretical framework without empirical elements, we dynamically build the patient-specific pressure-volume function and solved a long-standing inaccuracy problem of the BP industry. We have implemented the innovative algorithms on the prototype, initiated preliminary adult clinical testing, and filed four US patent applications. JBH has strong engineering expertise in medical device development. We also have partnered with neonatologists and cardiologists to benefit from their clinical experiences and insights. With this diverse, complementary team, we will advance our device from prototype to practice. Our tasks for this Phase I SBIR project include hardware redesigns and rigorous clinical tests. We will build our second-generation hardware and neonatal cuffs, which meet product specification matrixes. We will also validate the accuracy of neoBP against the standard of care UAC to demonstrate its feasibility. A successful comparative study in the NICU will be the milestone for the project to advance to Phase II. neoBP would be the first highly accurate non- invasive BP monitor in the NICU and provide a simple and reliable way to measure BP for all neonates. With accuracy comparable to UAC, neoBP will eliminate UAC-related complications and become an indispensable tool in every neonatologist's armamentarium. In Phase II, we will further test it in multi-center clinical studies, resolve any clinical related issues, redesign it for manufacturability, and receive FDA 510(k) clearance.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.