SBIR/STTR Research Award

Perovskite-Graphene Energy Integrating Detector for X-Ray Imaging

Award identifier cc994c26e5d109c0835bf6cc7ebda91779ebd3f3e67139a0da8d851d78ea97e9Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$246,965

Program and phase

SBIR · Phase I

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
KAIROS SENSORS LLC
Proposal award date
2021-09-30
Contract end date
2022-06-30
UEI
PQKKMHXUQLY9
Solicitation number
PA20-260
Topic code
NIBIB

Research abstract

Approximately 12% of women have a false-positive result after one mammogram, and 60% have a false positive after ten yearly mammograms - resulting in the need for secondary screenings. The cost of unnecessary secondary screenings, often due to the inability to differentiate between healthy and unhealthy tissue with the desired accuracy, has been calculated to be $4 billion per year. Increasing the sensitivity of low exposure per frame X-ray detectors will reduce the need for unnecessary secondary screenings and improve patient outcomes via enhanced image quality.Image quality largely depends on the response of the detectorandapos;s sensor to X-rays, aka sensitivity. Sensitivity is dependent on the sensorandapos;s ability to generate as many X-ray liberated charge carriers as possible that will contribute towards the signal acquisition for an image. Sometimes this is referred to as the sensorandapos;s average ionization energy or internal gain. Direct conversion sensors (semiconductors), such as amorphous selenium (a-Se), have a low internal gain – making low exposure per frame applications like tomosynthesis challenging to generate signals above the noise of the electronics.Recently, new materials such as organic/inorganic metal halide perovskites have drawn attention for their considerable stopping power of X-rays, efficient charge transfer properties, and ease of material synthesis. Additionally, graphene materials are known for their photoconductive gain and comfort of integration with conventional electronic platforms. Kairos Sensors LLC proposes a multi-pixel perovskite-graphene energy integrating detector for X-ray imaging with vastly improved sensitivity and low power consumption for this Phase I proposal.Kairos Sensorsandapos; innovation utilizes solution-processed perovskites grown directly from the conductive graphene lattice and has shown ultra-high sensitivity with prototype single-pixel perovskite-graphene devices. This project aims to achieve a multi-pixel perovskite-graphene detector with high sensitivity via optimized configuration of material composition and pixel dimensions.Phase I will focus on demonstrating an extremely sensitive multi-pixel perovskite-graphene detector. Phase II will focus on a more extensive pixel array and take images in preparation for commercialization.Clinicians widely use medical x-ray imaging for injury and disease detection within the body. Technology improvements that aim to reduce X-ray imaging costs and increase patient diagnoses, including the ability to distinguish between similar density tissue types, would improve patient outcomes based on medical imaging. The proposed medical imaging detector has extremely high sensitivity in detecting mammography energy X-rays. This technology also presents potentially lower manufacturing costs and demonstrates new technological advancements that will increase medical imaging systemsandapos; capability.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.