SBIR/STTR Research Award

A Smart Assistant for MRI Technologists

Award identifier bfdd66dd8a3b0d6f18b6dbc5f090ae24b9be969d428d10c41b43b5a5f62ba4d1Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$256,015

Program and phase

STTR · Phase I

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Biopac Systems, Inc.
Proposal award date
2021-09-20
Contract end date
2022-03-19
UEI
VKNKCPUQJ6V4
Solicitation number
PA20-265
Topic code
NIBIB

Research abstract

Abstract Magnetic resonance imaging (MRI) is critically important for pediatric care and the unusable data caused by patient motion has been estimated to cost $1.4B per year in the United States alone. Currently, a radiologist assesses if the images are satisfactory or not, but an MRI technologist does the imaging, and coordination of communication between the two is costly and slow. We propose to develop a device that monitors motion during an MRI scan without creating an MRI artifact or posing a burden to the subject. We propose to develop and assess a device based on MRI compatible MEMS technology that will measure motion and allow an MRI technologist to intervene to improve image quality by reminding the subject to hold still, and to assess the final image quality associated with the imaging data acquired. This will save valuable imaging time and reduce costs by improving the rate of diagnostic quality images, and save time by assisting the MR technologist to decide if the images are sufficient or if they need to be repeated. In this Phase I study, we will develop and validate an MRI compatible gyroscope and an MRI compatible magnetic field sensor, which in combination with an existing MRI compatible accelerometer will allow for rapid calibration of the device to the MRI coordinate system and the sensing of six degree of freedom motion. BIOPAC currently makes and sells an MRI compatible accelerometer. We will develop an MRI compatible gyroscope and magnetometer and a combined MRI compatible accelerometer/gyroscope in the same form factor as the current accelerometer. The sensor measurements will be converted to a digital signal through the existing BIOPAC MP160 hardware interface. We will write a software interface to enable each sensor to be used with the BIOPAC AcqKnowledge data acquisition software. These sensors will then be tested for their ability to operate safely in a clinical 3T MRI environment, tested for their ability to not create artifacts due to either RF interference or magnetic susceptibility changes, and tested for the accuracy of the sensor measurements in the MRI.Narrative Magnetic resonance imaging (MRI) is critically important for pediatric care and the unusable data caused by patient motion has been estimated to cost $1.4B per year in the United States alone. Currently, a radiologist assesses if the images are satisfactory or not, but an MRI technologist does the imaging, and coordination of communication between the two is costly and slow. We propose to develop an MRI compatible MEMS device that monitors motion during an MRI scan in order to assist the MRI technologist to see motion while it is occurring, to intervene to mitigate motion while the imaging is being acquired, and to determine if the final images formed are of diagnostic quality or not. This will save valuable imaging time and reduce costs by improving the rate of diagnostic quality images, and save time by assisting the MR technologist to decide if the images are sufficient or if they need to be repeated.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

2 SBIR/STTR records share this UEI (2021–2023). Reported award amounts total $1,598,607. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.