SBIR/STTR Research Award

Fully Automated Basic Life Services Resuscitation System to Improve Survival after Cardiac Arrest

Award identifier 805da79c56057c00ee0037792862cde5bb2986cbb7897dea2de1204040f363c8Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$383,376

Program and phase

SBIR · Phase I

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
AdvancedCPR Solutions LLC
Proposal award date
2021-09-01
Contract end date
2022-08-31
UEI
EUSBYXSC3KX7
Solicitation number
PA20-260
Topic code
NHLBI

Research abstract

Abstract The overall goal of this application is to improve neurologically-intact survival rates after sudden cardiac arrest (SCA). Still a leading cause of death, andlt;10% of the more than 600,000 SCA patients in the US each year survive with favorable neurological function. We propose to develop and evaluate a novel comprehensive Head Up (HUP) cardiopulmonary resuscitation (CPR) System designed primarily to allow Basic Life Services (BLS) providers (a fire crew without paramedics) to rapidly deliver fully automated CPR, including for the first time, automated synchronized mechanical positive pressure ventilation (PPV), to increase the likelihood of neurologically intact survival after SCA and increase crew safety. The proposal focuses on further developing and delivering an innovative all-in-one device for BLS teams based on our most recent breakthroughs in optimizing brain perfusion during SCA using controlled sequential elevation of the head and thorax in combination with the use of Active Compression Decompression (ACD) CPR and an impedance threshold device (ITD). As demonstrated in a well-accepted porcine SCA model, HUP CPR combined with ACD CPR and an ITD uniquely harnesses gravity to enhance drainage of venous blood from the head and neck, lower intracranial pressure, and markedly increase systemic and cerebral blood flow and likelihood for survival. The overall objectives of this application are also supported by new clinical data from a CPR Registry of patients receiving HUP CPR suggesting this comprehensive approach may provide the most benefit when deployed rapidly. Moreover, in resource-strapped Emergency Medical Services (EMS) systems across the country there is a growing need to develop technology that minimizes the number of resources required to deliver high quality CPR that is best for patient outcomes and safer for rescue personnel. We propose to achieve these collective objectives by demonstrating that incorporation of automated positive pressure ventilation (PPV), synchronized to the decompression phase of an easy to deploy and fully automated HUP CPR system, is feasible and safe for BLS providers, will reduce CPR personnel resource requirements, and most importantly, will optimize chances for neurologically intact survival after SCA. This combination of innovations, described herein as the SAVE CPR System, represents the combination of Synchronization, ACD+ITD, Ventilation, and Elevation. As such, the Specific Aims are: 1) Design and prototype an improved Head Up CPR device which includes automated PPV that is synchronized with the decompression phase of ACD CPR; 2) Determine if the SAVE CPR System will increase 24-hour survival with favorable brain function when implemented immediately after 10 minutes of untreated cardiac arrest compared with a delayed implementation strategy whereby SAVE is initiated after 10 minutes of untreated cardiac arrest and 8 minutes of conventional CPR to simulate Advanced Life Support (ALS) rather than BLS deployment of the SAVE CPR System; and 3) Test the feasibility of use of the SAVE CPR System by BLS providers in simulated cardiac arrest scenarios using manikins and human cadavers to determine if rescuers can rapidly deploy and utilize the SAVE System and to evaluate what potential improvements are necessary for a commercially viable version. We anticipate being able to demonstrate a) the ability to incorporate a PPV delivery device into the SAVE CPR System b) pre-clinical proof-of-concept that the SAVE CPR System will significantly improve neurologically-sound survival in pigs when deployed rapidly versus deploying the SAVE CPR System after a period of traditional conventional CPR, and c) that the SAVE CPR can be easily and rapidly applied by BLS providers.Project Narrative The overall goal of this application is to improve neurologically-intact survival rates after sudden cardiac arrest (SCA). Still a leading cause of death, less than 10% of the more than 600,000 SCA patients in the US each year survive with favorable neurological function. Phase 1 funding will support the development of a novel means to provide automated ventilation to cardiac arrest victims in addition to controlled sequential elevation of the head and thorax to improve cerebral blood flow and automated mechanical cardiopulmonary resuscitation (CPR) which is designed to be applied by first responders so that time to application of these life-saving technologies is shortened. These advances have the potential to increase survival with favorable neurological function in victims of SCA.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

4 SBIR/STTR records share this UEI (2017–2022). Reported award amounts total $3,000,897. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.